Download Print this page
Billyoh Darcy Assembly Manual
Billyoh Darcy Assembly Manual

Billyoh Darcy Assembly Manual

Reverse apex summerhouse

Advertisement

Quick Links

Assembly Guide -
Please read your Instructions thoroughly and please retain for future reference
Covers Sizes:
10FT GABLE:
12x10, 14x10
8FT GABLE:
10x8, 12x8
Covers Products:
19/28mm
Darcy and Riley
Before
You
Start
1) Reacquaint yourself
with the parts on the Tech
Document.
Reverse Apex Summerhouse
Build within 1 month of receiving product
Darcy
Covers All 8ft & 10ft Gable Sizes
Single Door Full Glazed
Riley
Covers All 8ft & 10ft Gable Sizes
Single Door Full Glazed
2) Read the instructions
thoroughly and then
re-read if necessary.
Darcy
Covers All 8ft & 10ft Gable Sizes
Double Door Full Glazed
Riley
Covers All 8ft & 10ft Gable Sizes
Double Door Full Glazed
3) Group all boards by Walls/Floor/Roof
together rst to make assembly easier.
Ensure all parts are there before assembly.
Single and Double
Doors Covered
Darcy/Riley
Double Door
CODE:
INS-0052
Treatment
4) We recommend to paint boards
after assembly to get the best
quality nish.
Please note that all images are for illustration purposes only.
Darcy/Riley
Single Door
V4.1-260919

Advertisement

loading
Need help?

Need help?

Do you have a question about the Darcy and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Billyoh Darcy

  • Page 1 Double Door Full Glazed Covers Products: Darcy/Riley Darcy/Riley Double Door Single Door CODE: 19/28mm Darcy and Riley INS-0052 Riley Riley Covers All 8ft & 10ft Gable Sizes Covers All 8ft & 10ft Gable Sizes Single Door Full Glazed Double Door Full Glazed...
  • Page 2 01909 768 858 PAGE 01 For Queries and Help please call Product Support: IMPORTANT SAFETY NOTICES GENERAL RECOMMENDATIONS Thank you for purchasing this building. We hope you will be delighted with your new building for many years to come. GARDEN BUILDINGS: THESE PRODUCTS ARE INTENDED FOR DOMESTIC AND OUTDOOR USE ONLY. These instructions have been written as a guide to assembling this building and will provide you with an overview of the process of constructing this building.
  • Page 3 01909 768 858 PAGE 02 For Queries and Help please call Product Support: PRODUCT MAINTENANCE CHECK LIST: STORAGE/ASSEMBLY Level Base: We Recomend that the building is assembled within 1 month of recieving the building. maintaining the building. Seal The Windows: STORAGE - The timber pack must be kept raised Use a silicone sealant on the inside and outside of the windows as soon as possible after assembly is a strong way of sealing the windows.
  • Page 4 Log Cabin Timber Movement PAGE 03 Maintenance: 2 weeks after build & on-going - Due to the nature of timber and the Interlocking style the building will want to settle and move. Follow the stages for the explanation of timber movement and the prevention/solution of issues.
  • Page 5 0 1 9 0 9 7 6 8 8 5 8...
  • Page 6 0 1 9 0 9 7 6 8 8 5 8...
  • Page 7 Exploded View - 10x8 Interlocking Apex Log Cabin Single Door Roof Felt (Comes in roll(s)) Roof Sheet (RSS) Finial (FI) Fascia Board (FB) Fascia Board (FB) Purlins (PU) Wall - D Wall - C Wall - A Wall - B Single Door (SD) Floor Window Glazing (GL)
  • Page 8 Exploded View - 12x8 Interlocking Apex Log Cabin Double Door Roof Felt (Comes in roll(s)) Roof Sheet (RSS) Fascia Board Finial (FI) (FB) Fascia Board (FB) Purlins (PU) Wall - D Wall - C Wall - A Wall - B Double Door (DD) Window Glazing (GL) Floor...
  • Page 9 Exploded View - 12x10 Interlocking Apex Log Cabin Double Door Roof Felt (Comes in roll(s)) Roof Sheet (RSS) Fascia Board Finial (FI) (FB) Fascia Board (FB) Purlins (PU) Wall - D Wall - C Wall - A Wall - B Double Door (DD) Window Glazing (GL) Floor...
  • Page 10 Exploded View - 14x10 Interlocking Apex Log Cabin Double Door Roof Felt (Comes in roll(s)) Roof Sheet (RSS) Fascia Board Finial (FI) (FB) Fascia Board (FB) Purlins (PU) Wall - D Wall - C Wall - A Wall - B Double Door (DD) Window Glazing (GL) Floor...
  • Page 11: What You Need

    01909 768 858 For Queries and Help please call Product Support: Pilot Drilling What you need IMPORTANT: Pre pilot drill all screw holes This is needed for all screw codes: S25, S30, S40, S50, S70 and S100 Recommend x2 for speed Roof options, Door &...
  • Page 12 01909 768 858 For Queries and Help please call Product Support: No Floor Assembly Place the Floor Surround around S50 x 4 Back Back Back Side 43mm Front Front Front Fix the frames at the corners. S50 x 22 Check technical details for sizes and layout.
  • Page 13 01909 768 858 For Queries and Help please call Product Support: Gable Top S70 x 4 Fit the last board on the rear wall, Continue building board above the door on the front up the Wall Boards wall and the bottom gable board. Gable Top S70 x 3 S50 x 12...
  • Page 14 01909 768 858 For Queries and Help please call Product Support: S50 x 12 19mm=126mm 28mm=117mm Line up the external Eaves Framing Repeat previous stage for this side on top of side wall boards R4C-28x28 (x2) R4C-28x28 (x2) Check the Tech Details Check the Tech Details S40 x 6 S40 x 6...
  • Page 15 01909 768 858 For Queries and Help please call Product Support: Position the Roof Sheet square with N30 x 12 and push up to the centre Push the Roof Sheet up to the centre. This will require 2 people N30 x 12 N30 x 12 make the building ridgid.
  • Page 16: Roof Assembly

    01909 768 858 For Queries and Help please call Product Support: Roof Assembly (T&G-8ft Gable) Roof Assembly (T&G-10ft Gable) N30 x 12 Push the Roof Sheet up to the centre. This will require 2 people make the building ridgid. Roof Assembly DFS x 1 S50 x 4 Line up Left Door Framing,...
  • Page 17 Line up the Door Side Framing, S50 x 4 ensure top and bottom distance Line up Top Door Framing, is 1490mm. Darcy Riley and pushed up tightly to 1490mm the wall boards Fixing Window Fixing Window Glazing PP x 26...
  • Page 18 S30 x 6 481mm 481mm Door Fixing Stage Fixing Opening Window centrally to the opening window. 2 people will be required for this. Riley Darcy S30 x 18 S30 x 6 CS x 1...
  • Page 19 01909 768 858 For Queries and Help please call Product Support: Fixing Door Glazing PP x 40 GL x 2 PP x 12 DR-SI Place the Glazing in the 1730mm S30 x 22 DR-TS around the edges 1490mm Fixing Front Wall Framing S30 x 10 Fix the Door Cloaking...
  • Page 20 01909 768 858 For Queries and Help please call Product Support: Fixing Rear Wall Framing Repeat for Rear of Building Use the provided Cloaking strips to cover the gaps as shown. Use the provided Cloaking strips S40s/strip. to cover the gaps as shown. S40s/strip.
  • Page 21 01909 768 858 For Queries and Help please call Product Support: Fold over Corner 100mm Repeat previous stages 100mm for this side Facia Fixing Stage Door Latch Fixing FI-01 FB-01 1403mm N30 x 12 N30 x 4 S30 x 8...
  • Page 22 01909 768 858 For Queries and Help please call Product Support: Protect your building Protect your building Protect your building 10x8 Interlocking Windowed Shed 12x8 Interlocking Windowed Shed 12x10 Interlocking Windowed Shed Please refer to page 3 for Please refer to page 3 for Please refer to page 3 for the required building the required building...

This manual is also suitable for:

Riley