Line voltage electric baseboard heat thermostat
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Line Voltage
Electric
Baseboard Heat
Thermostat
Owner's Manual
Read and save these
instructions.
For help please visit
honeywellhome.com
Application
Your new CT60 Series Electric Heating Thermostats provide line voltage control
of electric baseboard healing systems within the ratings listed on the front of
this instruction sheet. CT6OA replaces 2 wire thermostat; CT60B replaces 4 wire
thermostat. Wire connectors are not supplied. Use certified wire connectors approved
for No. 12 wires.
WARNING Electrical Shock Hazard.
This thermostat is a line voltage control (120–240 Volts). Do not install it if you
are not completely familiar with house wiring. If handled improperly, there is
risk of electric shock hazard, which may cause serious injury or death.
Specifications
CT60A single-line break 2 wires
CT60B double-line break in OFF position—4 wires
Temperature Range: 10° C to 30°C temperature range
Electrical Ratings: 60 Hz noninductive; 22A at 120-240 Vac; 19A at 277 Vac
CT60A,B

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Home CT60A

  • Page 1 This thermostat is a line voltage control (120–240 Volts). Do not install it if you are not completely familiar with house wiring. If handled improperly, there is risk of electric shock hazard, which may cause serious injury or death. Specifications CT60A single-line break 2 wires • CT60B double-line break in OFF position—4 wires •...
  • Page 2: Preparation For Installation

    ATTENTION: MERCURY RECYCLING NOTICE This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash. For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at...
  • Page 3 ELECTRIC HEATER (HOT) M35684 Fig. 1 CT60A wiring diagram. 1. Power supply provide disconnect means and overload protection as required. 2. Special service co/air solderless connectors must be used when connecting with aluminum conductors. Otherwise a fire hazard may result.
  • Page 4: Check Out Thermostat

    Check Out Thermostat 1. Turn temperature setting dial fully counter clockwise 2. Turn the power back on. 3. Turn the temperature setting dial fully clockwise listen for the “click” sound as switch makes contact. Electric heater should warm up within 2 - 10 minutes.
  • Page 5 1-year limited warranty Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).
  • Page 6 33-00145EF—03 M.S. Rev. 06-19 | Printed in United States This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502 © 2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.
  • Page 7: Caractéristiques

    Votre nouveau thermostat CT60 pour chauffage électrique assure la régulation tension secteur des plinthes chauffantes selon les caractéristiques nominales ci-dessus. Le CT60A peut servir à rem placer un thermostat bifilaire; le CT60B peut servir à remplacer un thermostat à 4 fils. Les connecteurs ne sont pas fournis. Utiliser des con necteurs certifiés, approuvés pour les fils n°...
  • Page 8: Avant L'installation

    ATTENTION : AVIS RELATIF AU RECYCLAGE DU MERCURE Ce produit ne contient aucun mercure. Cependant, ce produit peut remplacer un produit qui contient du mercure. Le mercure et les produits contenant du mercure ne doivent pas être jetés aux ordures ménagères. Pour obtenir plus d›informations pour savoir comment et où...
  • Page 9 APPAREIL DE CHAUFFAGE (CHAUD) MF35684 Fig. 1 CT60A, schéma de câblage. 1. Alimentation, fournir, au besoin, un dispositif de coupure et une protection contre les surcharges. 2. Utiliser des connecteurs sans soudure co/air pour usage spécial si les conducteurs sont en aluminium. Sinon, il peut Y avoir un risque d’incendie.
  • Page 10: Dépannage

    Vérification 1. Tourner le bouton de réglage du point de consigne dans le sens antihoraire ( ) jusqu’au bout. 2. Remettre le circuit d’alimentation sous tension. 3. Tourner le bouton de réglage du point de consigne dans le sens horaire ) jusqu’au bout;...
  • Page 11 Garantie limitée d’un an Resideo garantit ce produit, à l’exception des piles, contre tout défaut de pièce ou de main-d’oeuvre, durant une période d’un (1) an à partir de la date d’achat par le consommateur d’origine si le produit est utilisé et entretenu convenablement.
  • Page 12 33-00145EF—03 M.S. Rev. 06-19 | Imprimé aux États-Unis Ce produit est fabriqué par Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502. © 2019 Resideo Technologies, Inc. La marque de commerce Honeywell Home est utilisée sous licence avec l’autorisation d’Honeywell International Inc. Tous droits réservés.