SENSOR-SPECIFIC MESSAGES
Chapter 5 – Sensor-Specific Messages
Uplink Messages
The following table shows sensor specific uplink messages (sensor to web application). Uplink messages common
to all sensors are in the previous chapter.
Button ID
0x03
0x03
0x03
The first byte is the button identifier and always 0x03 for the single push button.
Downlink Messages
The following table shows sensor specific downlink messages (sensor to web application). Downlink messages
common to all sensors are in the Common Messages chapter.
Byte
0
1
2
Hold Delay
Hold delay defines how long the button must be held before it sends a button held event. Values range from 0-20
in 250ms increments (0-5 seconds). If set to 0, the hold delay doesn't send an event message.
The following table shows disable event bit definitions.
Byte
7:3
2
1
0
LED Configuration
To control LED behavior, use the LED configuration byte defined in the following table.
Only available in firmware v2.0 or newer.
Bits
Description
7:3
Unused
16
Event Payload
0x00
0x01
0x02
Description
Disable events (Refer toDisable Event Bit Definitions under
Hold delay
LED config (version 2.0 or later)
Description
Unused
Disable button hold event. Set to disable, clear to enable.
Disable button released event. Set to disable, clear to enable.
Disable button pressed event. Set to disable, clear to enable.
Description
Button pressed
Button released
Button held
TM
Reveal
Wireless Single Push Button User Guide
Hold
Delay.