Troubleshooting

When your sunbed or part of it (top, bed or facial) does not function, please check:
-
the fuses/differential switch of your main supply;
-
the connection to the main supply and fuse (Fig. 8 and Fig.9).
-
the thermal switches (temperature safety), these are checked by the IQ Touch Control, read
the user manual of the IQ Touch Control for more information;
-
the (possible) plug connection between the different parts (for example the ballast tray, base,
top or bodycooler, Fig.7:Z1, X2, X3);
-
the broken-glass sensors for the facials;
If one of the lamps does not function anymore, change it with the lamp next to it. If it still does
not work, change the starter;
If the facial(s) not work, check if the switch is the correct position;
If the top does not stay in the required positions or it moves up and down by itself, the spring
coils in the compartments B1 and B2 (Fig. 14) need to be adjusted;
Switch off the power supply to the machine in case of:
-
working inside the sunbed;
-
fans are out of order;
-
any doubt of the nature of the failure;
Please contact your technical service in case the problem cannot be solved with the above
mentioned possibilities;

Maintenance

After 50 hours or at least after one month and then every 500 hours or 6 months:
Visual inspection of all parts inside the sunbed;
Remove dust and fluffs inside;
Check the working of the whole machine;
Control screws and nuts (if loose tighten);
Clean the filters of the facials;
Always:
Pay attention to strange noises in the sunbed;
Clean the acrylics after every tanning session;
Consult an authorised service agent in the event your Ultrasun machine has a failure;