en - Technical data

Water connections

Cold water connection

Required flow pressure
Maximum flow rate (if no hot water and hard water supply)
Maximum flow rate
Threaded union required (to be provided by customer in accordance with DIN 44991, flat
sealing)
Length of water inlet hose supplied
*With liquid dispensing

Hot water connection (for variants with reduced heater rating)

Hot water connection (for variants with reduced heater rating)
Required flow pressure
Maximum flow rate
Threaded union required (in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Hard water connection

Required flow pressure
Maximum flow rate
Threaded union required (in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Waste water (drain valve)

Maximum waste water temperature
Machine-side drain connection (external diameter)
On-site drain (internal diameter)
Maximum flow rate
A vented combined pipe is required to drain the waste water. If several machines are connected to a single drain pipe, this should be
sufficiently large to allow all machines to drain simultaneously.

Securing the machine

Fittings

4 x wood screws DIN 571 (Ø x length)
4 x plugs (Ø x length)
Fixing the machine in place is absolutely essential.
Fastenings for floating screed must be supplied by the customer on site.

Emissions

Average heat dissipation rate to installation room
Emission sound pressure level in the workplace
Sound power level, washing
Sound power level, spinning
34
100–1000 kPa (1–10 bar)
74 (79,5*) l/min
26 (31,5*) l/min
3/4"
1550 mm
100–1000 kPa (1–10 bar)
74 (79,5*) l/min
1550 mm
100–1000 kPa (1–10 bar)
32 l/min
3/4"
1550 mm
95 °C
HT DN 70
75 x 1,9 x 110 mm (Muffe DN 70)
200 l/min
12 mm x 90 mm
16 mm x 80 mm
4,7 MJ/h
78 dB(A) re 20 µPa
60,3 dB (A) re 1 pW
82,2 dB (A) re 1 pW
90°