5. Connection Procedure (See Figure 3)
The procedure for connecting the M30290T-80FPD is shown
below.
(1) Mount the NQPACK080SD-ND on the user system.
(2) Attach the YQPACK080SD on the NQPACK080SD-ND.
(3) Secure the four corners of the YQPACK080SD with the
YQ-GUIDE's.
● Do not use the screws included with the
YQPACK080SD for fixing the YQPACK080SD.
● The screwdriver included with the
NQPACK080SD-ND is used for fixing the
HQPACK080SD. Do not use it for fixing the
YQ-GUIDE's.
(4) Attach the M30290T-EPB or M30290T2-CPE and the
M30290T-PTCB.
(5) Attach the M30290T-80FPD to the NQPACK080SD-ND.
6. External Dimensions and a Sample Foot Pattern (See Figure 4)
41.0
Figure 4 External dimensions and a sample foot pattern of the M30290T-80FPD
(4)
M30290T-PTCB
YQ-GUIDE (x4) *
YQPACK080SD *
NQPACK080SD-ND *
Figure 3 Connection procedure of the M30290T-80FPD
0.25
0.5
(3/4)
M30290T-EPB
or
M30290T2-CPE
M30290T-80FPD
(5)
Be sure to use a
Phillips screwdriver.
(3)
(2)
(1)
80-pin 0.5-mm-pitch
(80P6Q-A) foot pattern
11.1
15.1
Unit: mm