Operation Check

For NavNet TZtouch3 and NavNet TZtouch2, the DFF3-UHD is powered on/off from the ship's switchboard.
The STATUS LED and ERROR LED on the bottom of the DFF3-UHD lights or blinks according to equipment
state, as described in the table below.
LED Type
LED State

Troubleshooting

The table below provides basic troubleshooting procedures which the user may follow to restore normal op-
eration. If you cannot restore normal operation, do not check inside unit. Have a FURUNO dealer check the
.
equipment
Cannot turn on power.
No echo appears but fixed
range scale appears.
Sensitivity is low.
ERROR LED turns on.
STATUS
Blinking every two seconds
Blinking every 0.4 seconds
Off
LED Position
Problem
• The power cable is disconnected or damaged. Check the
power cable and if it damaged, replace it.
• Check the ship's mains and check if the switchboard is
turned on.
• Check the fuse on the power cable. If the fuse has blown,
find the cause then replace it.
• The sensor cable is disconnected or damaged.
Check the cable and reconnect or replace it as necessary.
• Gain setting is too low. Raise the gain.
• Marine life is adhering to the transducer face. Clean the
transducer face.
• Vessel is in heavily sedimented water.
• Disconnect the Power cable and LAN cable.
• Connect the Power cable and LAN cable.
• Contact your local dealer for advice when the problem
cannot be solved.
ERROR
Off
Normal operation
Off
Transducer settings at NavNet
device not properly set.
Communication error with
Lit continuously
NavNet device or internal fan
error (see "Troubleshooting"
about how to solve the prob-
lem).
Reason