www.moderator.com.pl
Once a year before heating season it is recommended to conduct a
chargeable review and maintenance of Biomaster set by an authorized
Moderator service (tel. 506 368 455).

5. Safe operation conditions

The basic condition for safe operation is the preparation of the installation
and safety measures in accordance to Polish norms.
To preserve safe operating conditions, please abide to the following rules:
 use protective gloves and eyewear
 do not block the covers and doors
 avoid opening the doors when the fan is activated
 use 24V portable lamps
 keep the boiler room clean
 maintain the boiler and its installation in a good technical
condition
 pay attention to the tightness of the installation
 electrical installation can be serviced only by a qualified
electrician
 in the winter season avoid intervals in heating
If you suspect freezing of water in the installation, check the water
flow in the safety pipes. Water added to the installation should flow
from the overflow pipe from the expansion tank. In case of
obstruction, do not ignite the boiler follow the instructions for
emergency shutdown (ch. 3.5).
It is forbidden to:
 pour water on the boiler
 ignite the boiler with flammable liquids

6. Storage and boiler transport

The boilers can be stored in unheated buildings, necessarily with roofing
and ventilation The boilers must be transported in an upright position Lifting
and lowering of the boilers should be done with mechanical lifts, for example, a
forklift When elevating the boiler, it is forbidden to lift it with straps connected
to any protruding elements such as doors, handles, screws, etc., as it may
result in an accident and damage the boiler.