Viewing debug data on the KitProg serial port of the kit

Please ensure that you have installed either ModusToolbox™ or CYPRESS™ programmer before using the Rapid
IoT connect developer kit KitProg3 USB-UART bridge. KitProg3 enumerates as a root USB Composite Device with
subordinate CMSIS-DAP, Bridge, and USB-UART interfaces.
Please open "TeraTerm" / "Minicom" / other serial terminal software installed in your laptop/ PC and select
"KitProg3 serial port", with following settings to view the debug data of the kit locally on your PC / laptop.
Baud rate:
115200
Data:
8
Parity:
None
Stop Bits:
1

Reading LEDs

Rapid IoT connect has four LEDs onboard. Please refer to the below picture for the same.
LED4 power LED is the leftmost LED on the picture. It glows in blue colour. This LED is always on when there is
a powered USB cable or battery is connected to the Rapid IoT connect device.
LED5 charge LED is the next LED to the power LED. It glows in yellow colour. This LED blinks when the battery
connected to the Rapid IoT connect developer kit is getting charged by the powered USB cable. This turns off
when the battery is fully charged.
LED2 user LED is the next LED in sequence from left to right after the USB connector. This LED glows in red
colour. This LED is available for user configuration. This LED also denotes an error message if it is blinking
during the booting.
LED3 Kitprog3 LED is the last LED from left to right sequence. This LED glows in yellow colour. This LED glows
continuously if the device is connected to the PC with right drivers installed and loaded.

Troubleshooting guide

Password missing after new user sign-up
5.
Possible cause:
Email has gone to junk/spam folder of your mailbox.
You may have entered wrong email id while registering.
Possible solution:
A mail from no-reply@infineon.com with your username and temporary password will be sent and check in
spam/junk folders if you have received already. You will be prompted to change the password upon logging
for the first time.
Verify the email address entered during user registration. If it is wrong, register again with the correct email
address.
Build failed / status not updated
6.
Possible cause:
Mismatch in the serial number of the Rapid IoT connect developer kit
45 of 54
2022-25-04