INSTALLATION

The 2406LR comes in a die cast enclosure with integral mounting flanges. It is recommended that the
enclosure be mounted on a flat surface with the connectors facing down. For units with the -WP
option exposed to the elements, while not required to prevent water ingress into the unit, good outdoor
installation practice suggests the use of waterproof connectors, boots and/or protecting connectors
with a wrap of Scotch 130C rubber tape followed by Scotch Super 88 vinyl tape, or equivalent.
2.1.

2406LR CONNECTIONS

Coaxial connectors accept conductors in the range of 23-18 AWG (0.26-0.82
2
mm
). Using a larger conductor will damage the connector. If you are using
cable with a center conductor larger than 18 AWG (0.82 mm
fixed or crimp pin of a suitable diameter must be.
RF OUTPUT 1,2:
F-Type connector for L-band satellite signals.
DC INPUT:
Input F-Type connector for DC power supply. Input power supply range is from 11-20
VDC.
Do not exceed 21VDC at the DC input connector or damage to the unit will
result.
L-Band/Wideband Standalone Fiber Receiver
Figure 2-1: 2406LR Module