PRE-UNCRATING CHECKLIST
WARNING: DO NOT CONNECT THE MACHINE USING A POWER CORD AND PLUG OR AN
EXTENSION CORD OF ANY KIND.
WARNING: KITCHENS ARE WET ENVIRONMENTS WHICH REQUIRE ALL ELECTRICAL
CONNECTIONS TO BE "LIQUID TIGHT".
ELECTRICAL INSTALLATION MUST CONFORM TO ALL APPLICABLE LOCAL
WIRING CODES. ALL ELECTRICAL CONNECTIONS MUST BE "LIQUID TIGHT"
AND READILY ACCESSIBLE FOR INSPECTION AFTER INSTALLATION
WITHOUT MOVING THE POWER PREP INTRO MACHINE.
VERIFYING SYSTEM REQUIREMENTS
Prior to completely removing the Power Prep Intro unit from the crate, it is necessary to
verify certain requirements. Remove only the lid of the crate at this time.
Verifying System Direction
The Power Prep Intro can be built as a "Left to Right" or as a "Right to Left" configuration
with a variety of options. Look inside the crate and verify that the configuration of the
machine matches the specifications of the order description.
The information in this document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands.
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing
our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2022 Unified Brands. All Rights Reserved.
This manual provides information for:
POWER PREP INTRO
Verifying the Electrical Requirements
The electrical requirements for the machine are on the machine identification tag
located on the side of the wash tank, next to the motor. The electrical service in the
facility where the machine is to be installed must be rated for the capacity shown on the
identification tag. This machine will require a permanently mounted disconnect that is
in a "liquid tight" enclosure. Do not use an in-line plug for disconnecting the machine
from the electrical source. Contact a licensed and certified electrician for the enclosure
installation using the appropriate breaker (overcurrent protection) and wire size for the
machine's electrical service.
PART NUMBER 36526, REV. B (09/20)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the power soak INTRO and is the answer not in the manual?

Questions and answers

Summary of Contents for Unified Brands power soak INTRO

  • Page 1 The information in this document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands. Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing...
  • Page 2: Component Installation

    POST-UNCRATING INSTRUCTIONS WARNING: FAILURE TO LOCK OUT AND TAG OUT THE ELECTRICAL AND WATER SUPPLIES MAY RESULT IN PERSONAL INJURY OR DEATH AND EXTENSIVE UNCRATING EQUIPMENT DAMAGE. Remove From Crate IMPORTANT: BE SURE TO LEAVE ENOUGH OF THE EXISTING PIPING FOR THE INSTALLATION OF NEW SHUTOFF VALVES.
  • Page 3 While holding the drain body to prevent it from rotating, tighten the drain nut with a IMPORTANT: THE RIM OF THE DRAIN MUST SEAT IN THE RECESS OF THE SINK OR IT wrench to firmly seat the nut against the rubber vibration ring and the vibration ring WILL WORK LOOSE OVER TIME AND ALLOW WATER TO LEAK AROUND THE against the surface of the sink (approximately ¼...
  • Page 4: Completing The Installation

    IMPORTANT: CHEMICAL DISPENSER AND CHEMICALS FOR THE POWER PREP INTRO Machine Placement MUST BE OBTAINED FROM A SOURCE OTHER THAN UNIFIED BRANDS. Position the Power Prep Intro so that the back splash rests against the wall and is Chemical Dispenser Connection placed according to the floor plan or customer’s selected location.
  • Page 5: Validating The Installation

    Checking the Motor Rotation IMPORTANT: CHEMICAL DISPENSER AND CHEMICALS FOR THE POWER PREP INTRO MUST BE OBTAINED FROM A SOURCE OTHER THAN UNIFIED BRANDS. The motor must rotate in the correct direction in order for the Power Prep Intro to function properly.