Unified Brands Randell DROP-IN 9550-290 Operator's Manual

Freezer/plate chiller
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
888-994-7636, fax 888-864-7636
unifiedbrands.net
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING R290 flammable refrigerant in use. Improper installation,
adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the
consignee to inspect the container upon receipt of same and to determine
the possibility of any damage, including concealed damage. Unified
Brands suggests that if you are suspicious of damage to make a notation
on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
EQUIPMENT DESCRIPTION
MODEL
LENGTH
DEPTH
9550-290
28.375"
17.1875"
9552-290
28.375"
28.375"
INSTALLATION
CAUTION: THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT. USE CAUTION WHEN
HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER. AVOID
DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A LEAK.
WARNING: FAILURE
TO
FOLLOW
RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.
WARNING: IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE.
CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE
FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON
THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING
VOLTAGE LIMITS WILL VOID THE WARRANTY.
THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL NOT
OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 104V.
WARNING: THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL,
INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE
SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15.
NO. OF
STORAGE
HEIGHT
OPENINGS
(CUBIC FEET)
27"
1
1.8
27"
1
3.36
INSTALLATION
GUIDELINES
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends
referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2019 Unified Brands.
All Rights Reserved.
This manual provides information for:
9550/52-290 DROP-IN SERIES
FREEZER/PLATE CHILLER
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE: Due to a continuous program of product improvement, Unified Brands
reserves the right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain
recommended procedures are not followed, warranty claims will be denied.
MODEL NUMBER _________________________
SERIAL NUMBER _________________________
INSTALLATION DATE ______________________
The serial number is located in the cabinet left side
under the electrical box. An example is shown here.
POWER
GALLON
COUNTER
USAGE KW
CAPACITY
CUTOUT
(PER DAY)
6
26" x 15.75"
0.95
11.2
26" x 26"
1.34
SELECTING A LOCATION FOR YOUR NEW UNIT
The following conditions should be considered when selecting a location for your
unit:
AND
1. Floor & Countertop Load: The area on which the unit will rest must be level,
free of vibration, and suitably strong enough to support the combined weights
of the unit plus the maximum product load weight. NOTE: If there is a question
pertaining to weight load limits, consult the factory at 1-888-994-7636.
2. Secure & Seal: Once the drop in unit is installed into the counter it can be
secured to the countertop by using the brackets supplied from the factory.
a. Secure unit to top and seal with "NSF" approved silicone.
b. Install inside duct with thumb screws and adjust outside duct to fit
between condenser coil and counter's louvered cutout
c. Secure outside duct in place with screws through pre-punched holes.
PART NUMBER PP MNL1702, REV. E (08/19)
COMPRESSOR
VOLT
AMPS
1/4
115/60/1
2.0
1/4
115/60/1
2.0
SHIP WT
NEMA
(LBS)
5-15P
125
5-15P
165

Advertisement

Table of Contents
loading

Summary of Contents for Unified Brands Randell DROP-IN 9550-290

  • Page 1 Secure outside duct in place with screws through pre-punched holes. Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2019 Unified Brands.
  • Page 2: Installation Checklist

    IMPORTANT - READ FIRST - IMPORTANT NEAR EXPOSED REFRIGERANT TUBING INTERIOR EVAPORATOR COVER NEAR MACHINE COMPARTMENT AND NAMEPLATE EXTERIOR OF UNIT 3. Clearance: See installation diagrams for minimum compartment dimension. required, the control is located on the front panel. Confirm that the unit is Do not place any object that can block the ventilation exhaust from the holding the desired temperature.
  • Page 3: Operation

    CHANGE SET POINT: To raise temperature Unified Brands has attempted to preset the temperature control to ensure that 1. Press and hold “ ” to access set point. your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food type and your type of operation, you may need to alter 2.
  • Page 4: Maintenance

    HYDROCHLORIC ACID (MURIATIC ACID) ON STAINLESS STEEL. These services often offer guarantees as well as the flexibility in scheduling or maintenance for your convenience. For a complete listing of current Unified Brands Unified Brands strongly suggests a preventive maintenance program which would ASA please visit www.unifiedbrands.net.
  • Page 5: Troubleshooting

    TROUBLESHOOTING SERVICE This unit is designed to operate smoothly and efficiently if properly maintained. CAUTION: COMPONENT PARTS SHALL BE REPLACED WITH FACTORY OEM PARTS. However, the following is a list of checks to make in the event of a problem. Wir- SERVICE WORK SHALL BE DONE BY FACTORY AUTHORIZED SERVICE ing diagrams are found at the end of this manual.
  • Page 6: Parts List

    Parts List ITEM PART NUMBER DESCRIPTION RP CLP0102 HOLD DOWN CLIP COLD PANS AND PLATE CHILLERS RP COV1703 COVER, REMOVABLE COND UNIT HOUSING, 9550,9552-290 RP DGH1701 DOGHOUSE, INNER PORTION, 9550&52-290 (T17-0049E-D14) RP DGH1702 DOGHOUSE, OUTER PORTION, 9550&52-290 (T17-0049F-D17) RP LVR0003 LOUVER, 14"...
  • Page 7: Electrical Schematic

    Electrical Schematic OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER...
  • Page 8: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER...
  • Page 9 Les renseignements contenus dans ce document sont reconnus comme étant à jour et exacts au moment de la rédaction et de l’impression. Unified Brands recommande de consulter le site Web de nos gammes de produits, unifiedbrands.net, pour obtenir les renseignements et...
  • Page 10: Liste De Vérification Pour L'installation

    2. Fixer et sceller : Une fois que l’appareil encastré est installé dans le comptoir, dans le compartiment où l’appareil est installé. Il n’est pas permis d’utiliser il peut être fixé à l’aide des attaches fournies par Unified Brands. d’autres composants qui pourraient causer un arc électrique.
  • Page 11: Alimentation Électrique

    72,07 CM (28,375 PO) pourrait s’user ou tomber en panne prématurément. Unified Brands a tenté de prérégler la commande de température pour s’assurer 43,66 CM (17,188 PO) que votre appareil fonctionne à la température optimale, cependant, en raison des CONDUIT D’AIR RÉGLABLE conditions ambiantes, incluant l’altitude, le type d’aliments et l’utilisation, il est...
  • Page 12: Entretien

    Unified Brands, veuillez visiter notre site www.unifiedbrands.net. MISE EN GARDE ! : NE PAS UTILISER DE SOLVANTS DÉTACHANTS ABRASIFS, ET NE Unified Brands croit en la qualité des produits qu’il fabrique, c’est pourquoi il offre JAMAIS UTILISER D’ACIDE HYDROCHLORIQUE (ACIDE MURIATIQUE) SUR une des meilleures garanties de l’industrie.
  • Page 13: Dépannage

    DÉPANNAGE ENTRETIEN Cet appareil est conçu pour fonctionner de façon optimale et efficace s’il est MISE EN GARDE ! : LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES convenablement entretenu. Cependant, si vous rencontrez des problèmes, voici COMPOSANTS IDENTIQUES. LES TRAVAUX D’ENTRETIEN DOIVENT ÊTRE EFFECTUÉS PAR DU PERSONNEL D’ENTRETIEN AUTORISÉ...
  • Page 14: Liste Des Pièces

    Liste des pièces ITEM NUMÉRO DE PIÈCE DESCRIPTION RP CLP0102 PINCE DE RETENUE POUR LES RÉCIPIENTS FROIDS ET LES PLAQUES REFROIDISSANTES RP COV1703 COUVERCLE AMOVIBLE DU BOÎTIER DU CONDENSEUR, 9550,9552-290 RP DGH1701 PARTIE INTERNE DE LA HOUSSE, 9550&52-290 (T17-0049E-D14) RP DGH1702 PARTIE EXTERNE DE LA HOUSSE, 9550&52-290 (T17-0049F-D17) RP LVR0003 PERSIENNE À...
  • Page 15: Schéma Électrique

    Schéma électrique 16FLA(72RLA) 16(10)A 240V- TOUCHE DIRECTE LIGNES D’ALIMENTATION 120V 50-60hz COMP PRISE NEMA 5–15 BLANC VERT PROTECTION CONTRE LES SURCHARGES BLANC BRUN COMPRESSEUR VENTILATEUR DU CONDENSEUR COMPRESSEUR CONDENSATEUR DE MARCHE BLANC ALIMENTATION 115V–60HZ–1PH CORDE AVEC MISE À LA TERRE NEMA # 5–15P NOTE : NOIR (AIR) = S1...
  • Page 16: Journal D'entretien

    Journal d'entretien N° de modèle : Acheté de : N° de série : Emplacement : Date d'achat : Date d'installation : N° du bon de commande : Pour un appel de service : Date Entretien effectué Effectué par OM-9550/52-290 DROP-IN SERIES FREEZER/PLATE CHILLER...