OPERATOR/SERVICE MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
MODELS EE (CE)
STEAM JACKETED
KETTLES
· Self Contained
· Floor Mounted
· Stationary
· Electrically Heated
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER 127731 REV H (06/17)
International
888-994-7636, fax 888-864-7636
unifiedbrands.net

Advertisement

Table of Contents
loading

Summary of Contents for Unified Brands Groen EE Series

  • Page 1 Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier.
  • Page 2: Important Operator Warnings

    IMPORTANT - READ FIRST - IMPORTANT THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN CONFORMITY WITH THE INSTALLATION AND SERVICING INSTRUCTIONS AND NATIONAL REGULATIONS IN FORCE AT THE TIME. PARTICULAR ATTENTION MUST BE PAID TO THE FOLLOWING: I. E. E. REGULATIONS FOR ELECTRICAL INSTALLATIONS ELECTRICITY AT WORK REGULATIONS HEALTH AND SAFETY AT WORK ACT FIRE PRECAUTIONS ACT...
  • Page 3 IMPORTANT - READ FIRST - IMPORTANT WARNING: HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM BRANCH BEFORE SERVICING. FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR DEATH. WARNING: THIS UNIT IS INTENDED FOR USE IN THE COMMERCIAL HEATING, COOKING AND HOLDING OF WATER AND FOOD PRODUCTS, PER THE INSTRUCTIONS CONTAINED IN THIS MANUAL.
  • Page 4: Table Of Contents

    Table of Contents Important Operator Warnings ............page 2-3 References..................page 4 Equipment Description..............page 5 Inspection & Unpacking ............... page 6 Installation..................page 7 Initial Start-Up................page 8 Operation ................. page 9-10 Sequence of Operation ..............page 11 Cleaning................... page 12-13 Maintenance................
  • Page 5: Equipment Description

    Equipment Description Groen Model EE is a floor-mounted, stationary, steam-jacketed kettle which has a thermostatically controlled, self-contained, electrically-heated steam supply and appropriate controls, mounted on a sturdy base. Heat produced by electric heating elements boils water in a reservoir below the jacket to produce steam under pressure. The kettle is surrounded by air-insulated stainless steel sheathing.
  • Page 6: Inspection & Unpacking

    Inspection & Unpacking CAUTION The unit will arrive in a heavy shipping crate and will be banded to a skid. Immediately SHIPPING STRAPS ARE UNDER TENSION upon receipt, inspect the crate carefully for exterior damage. AND CAN SNAP BACK WHEN CUT. TAKE CARE TO AVOID PERSONAL INJURY OR Thoroughly inspect the unit for concealed damage.
  • Page 7: Installation

    Installation WARNING The Groen Kettle is provided with complete internal wiring and is ready for immediate INSTALLATION OF THE KETTLE MUST BE connection. Wiring diagrams are provided in this manual and on the inside of the DONE BY A CERTIFIED ELECTRICIAN OR control housing service panel.
  • Page 8: Initial Start-Up

    Initial Start-Up Now that the kettle has been installed, you should test it to ensure that the unit is IMPORTANT operating correctly. BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE 1. Remove all literature and packing materials from inside and outside of the unit. OPERATING INSTRUCTIONS, CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED 2.
  • Page 9: Operation

    Operation WARNING The operator controls kettle heating with the thermostat dial. The dial turns heating OPEN THE KETTLE LID CAREFULLY TO element power on or off and sets the kettle operating temperature. AVOID STEAM WHICH MAY ESCAPE. DIRECT CONTACT COULD RESULT IN A.
  • Page 10 Operation CAUTION 5. When removing baskets with cooked product, lift straight up, ensuring basket DO NOT OVERFILL THE KETTLE WHEN bottoms clear the kettle rim. Wear protective oven mitts and protective apron. COOKING, HOLDING OR CLEANING. KEEP LIQUIDS AT LEAST 5-8 CM (2-3 6.
  • Page 11: Sequence Of Operation

    Sequence of Operation The following “action-reaction” outline is provided to help the user understand how the equipment works. When the operator starts up the kettle by turning the power switch to ON (which lights the green POWER lamp) and turning the operating thermostat dial from “0” to a desired setting, the thermostat switch closes.
  • Page 12: Cleaning

    Cleaning WARNING 1. Suggested Cleaning Supplies: KEEP WATER AND SOLUTIONS OUT OF a. Cleaner, such as Klenzade HC-10 or HC-32 from ECOLAB, Inc. CONTROLS AND ELECTRICAL EQUIPMENT. b. Kettle brushes in good condition (and a bottle brush, for the draw-off). NEVER SPRAY THE SUPPORT HOUSING OR c.
  • Page 13 Cleaning CAUTION l. If there is difficulty removing mineral deposits or a film left by hard water or NEVER LEAVE A CHLORINE SANITIZER IN food residues, clean the kettle thoroughly and then use a deliming agent, like CONTACT WITH STAINLESS STEEL Groen Delimer/Descaler (Part Number 114800), in accordance with the manu- SURFACES FOR LONGER THAN 30 facturer’s directions.
  • Page 14: Maintenance

    Maintenance NOTICE: Contact Groen or an authorized representative when repairs are required. WARNING WHEN TESTING, AVOID ANY EXPOSURE 1. Periodic Maintenance TO THE STEAM BLOWING OUT OF THE A Maintenance & Service Log is provided at the back of this manual with the SAFETY VALVE.
  • Page 15 Maintenance WARNING 3. Jacket Filling and Water Treatment STAY AWAY FROM THE STEAM THAT IS The jacket was charged at the factory with the proper amount of treated water. You BLOWING OUT OF THE SAFETY VALVE. may need to restore this water because it was lost as steam during venting or by THE STEAM CAN CAUSE A SEVERE BURN.
  • Page 16: Troubleshooting

    Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item on the list is followed by X, the work should be done by a qualified service representative.
  • Page 17 Troubleshooting SYMPTOM WHAT TO CHECK Safety valve leaks a small User a. For contamination that prevents seating of valve. With full amount of steam when the pressure in the jacket, pull the lever all the way briefly to blow kettle is operating. the valve clean, then let the lever snap back to seat the valve.
  • Page 18: Parts List

    Parts List (Keyed to Drawings and Photographs on the Following Pages) To order parts, contact your Groen Certified Service Agency. Supply the model designation, part description, part number, quantity and, where applicable, voltage and phase. DESCRIPTION PART NO. DESCRIPTION PART NO. DESCRIPTION PART NO.
  • Page 19 OM/SM-EE(CE) 10.0 Parts List Parts List (Keyed to Parts List on Page 17) To order parts, contact your Groen Certified Service Agency. Supply the model disignation, part description, part number, quantity and, where applicable, voltage and phase. OM/SM-EE-CE OM/SM-EE-CE...
  • Page 20 OM/SM-EE(CE) 10.0 Parts List Parts List (Keyed to Parts List on Page 17) To order parts, contact your Groen Certified Service Agency. Supply the model disignation, part description, part number, quantity and, where applicable, voltage and phase. OM/SM-EE-CE OM/SM-EE-CE...
  • Page 21 OM/SM-EE(CE) 10.0 Parts List Parts List (Keyed to Parts List on Page 17) To order parts, contact your Groen Certified Service Agency. Supply the model disignation, part description, part number, quantity and, where applicable, voltage and phase. OM/SM-EE-CE...
  • Page 22 OM/SM-EE(CE) 10.0 Parts List Parts List (Keyed to Parts List on Page 17) To order parts, contact your Groen Certified Service Agency. Supply the model disignation, part description, part number, quantity and, where applicable, voltage and phase. 5 13 65 14 OM/SM-EE-CE OM/SM-EE-CE...
  • Page 23: Wiring Diagram

    Wiring Diagram EE-20, 208 VOLT, 3PH OM/SM-EE-CE...
  • Page 24 Wiring Diagram EE-20, 400 VOLT, 3 PH OM/SM-EE-CE...
  • Page 25 Wiring Diagram EE-40, 208 VOLT, 3PH OM/SM-EE-CE...
  • Page 26 Wiring Diagram EE-40, 400 VOLT, 3PH OM/SM-EE-CE...
  • Page 27: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM/SM-EE-CE...