WARNING:
All operation concerning installation, maintenance, and
other malfunction shall be done by qualified staff.
Do not leave flammable material in the vicinity of the sys-
tem. Make sure that all components of the system are po-
sitioned as required by regulations.
In the presence of noxious vapour or dust in the area of
installation, install a separate air handling system for the
product. Do not place fluid containers and other foreign
objects on the internal or external units.
Do not place flammable material in the vicinity of the instal-
lation. Do not use the external unit for treating water from
industrial processes, swimming pools or domestic water.
In such cases, install a heat exchanger upline of the exter-
nal unit. The device is not intended to be used by people
(including children) of reduced physical, sensory or mental
capacity, or who are not familiar or experienced with the
equipment, unless they have been trained or are super-
vised in the use of the equipment by a person responsible
for their safety.
Children must be supervised to ensure that they do not
play with the equipment or its packaging (staples, plastic
bags, polystyrene protection, etc.)
The product's protection panels and all maintenance and
hookup of electrical equipment must be done by qualified
staff.
WARNING!
This appliance can be used by children aged from 8 years
and above and person with reduced physical, sensory or
mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concer-
ning use of the appliance in a safe way and understand
the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children without
supervision.
This product conforms
to Directive
WEEE 2012/19/EU.
The symbol of the crossed waste paper basket on the
appliance indicates that at the end of its working life the
product should be disposed of separately from normal
domestic household rubbish, it must be disposed of at a
waste disposal centre with dedicated facilities for elec-
tric and electronic appliances or returned to the retailer
when a new replacement product is purchased.
The user is responsible for the disposal of the product
at the end of its life at an appropriate waste disposal
centre.
The waste disposal centre (which using special treat-
ment and recycling processes effectively dismantles
and disposes of the appliance) helps to protect the envi-
ronment by recycling the material from which the pro-
duct is made.
For further information about waste disposal systems
visit your local waste disposal centre or the retailer from
which the product was purchased.
56 / GB
CE Labelling
appliance complies with norms:
- 2014/30/EU - relating to Electromagnetic Compatibility
- 2014/35/EU - related to electrical safety (LVD)
- RoHS2 2011/65/EU related to the restriction of the use
of certain dangerous substances in electrical and elec-
tronic equipment (EN 50581)
- Regulation (EU) No. 813/2013 on ecodesign (no. 2014/C
207/02 - transitional methods of measurement and cal-
culation)
Cleaning the heating system
At the first installation, it is necessary to pre-clean the ins-
tallation. In order to ensure the proper functioning of the
appliance, after each cleaning operation or water substi-
tution, verify that the appearance of the liquid system is
clear, without visible impurities and that water hardness is
under 20°F.
Characteristics of the water supplied to the appliance
Ensure that the system is supplied with water having a
maximum hardness of 20 ° F.
For areas where the water is particularly hard, provide a
water softener does not change in any way the warranty,
if the component is installed in a proper manner and is
subject to regular checks and maintenance. In case of ag-
gressive water filling (the pH should be kept between 6.6
and 8.5), ferruginous or hard, use treated water in order to
prevent scaling, corrosion and damages to the appliance.
Please note that even a small amount of impurities in the
water may decrease the performance of the installation.
The used filling water must absolutely be treated in case
of installation of large capacity (high volumes of water) or
in case of frequent replenishments of water in order to
maintain a constant level of liquid in the installation. Where
it is necessary to proceed with the cleaning of the installa-
tion, fill the entire system with treated water.
Verify that the maximum pressure, at the level of the water
supply, does not exceed 5 bar. Otherwise, provide the
installation with a pressure reducer valve.
In order to prevent frost in the pipes, if risk conditions
are detected, the system provides automatic antifreeze
cycles. In case of power failure the antifreeze protection
is guaranteed by the Exogel Kit (nominal operating tem-
perature + 4 °C), which mechanically empties the system if
necessary. By properly installing the Exogel Kit, the plant
does not need any glycol.
Glycol negatively affects the performance of the heat
pump and is therefore strongly not recommended. If gly-
col is used, Ariston will not be responsible for system
efficiency losses and recommends a correct dosage and
maintenance.