Download Print this page

Trane ZSENS930AW00MA Installer's Manual page 4

Z-wave temperature & humidity sensor

Advertisement

Z-WAVE CONFIGURATION TABLE
Parameter
Description
1
Time between Battery Reports (hours)
2
Send BASIC SET ON above this temperature (See #20)
3
Send BASIC SET ON below this temperature (See #20)
4
Send BASIC SET OFF above this temperature (See #20)
5
Send BASIC SET OFF below this temperature (See #20)
6
Send multiple attempts for all BASIC SET commands
7
Temperature Units
8
Association Group1 – Temperature delta auto send threshold
9
Association Group1 – Periodic temperature send interval
10
Association Group2 – Temperature delta auto send threshold
11
Association Group2 – Periodic temperature send interval
12
Send BASIC SET ON above this humidity (See #20)
13
Send BASIC SET ON below this humidity (See #20)
14
Send BASIC SET OFF above this humidity (See #20)
15
Send BASIC SET OFF below this humidity (See #20)
16
Association Group1 – Humidity delta auto send threshold
17
Association Group1 – Periodic humidity send interval
18
Association Group3 – Humidity delta auto send threshold
19
Association Group3 – Periodic humidity send interval
20
BASIC SET options for temperature and humidity
21
Temperature Offset
22
Humidity Offset
23
Humidity Filter Time Constant
* Configurable through third party Z-Wave systems.
ASSOCIATION GROUP INFORMATION TABLE
GROUP
PROFILE
1
Lifeline
2
Sensor
3
Sensor
4
Sensor
5
Sensor
6
Sensor
FCC/IC NOTICES
FCC ID: WIBTZW020 - This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with
the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC ID: 9374A-W020 - This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'encompromettre le fonctionnement.
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient
indoor environments for residential applications. For more information,
please visit www.trane.com or www.americanstandardair.com
Representative-only illustrations included in this document.
18-HD83D1-5B-EN 26 Aug 2021
Supersedes 18-HD83D1-5A-EN (August 2020)
*
COMMAND CLASSES
Battery Report, Multilevel Sensor Report, Device Reset
Locally Notification
Multilevel Sensor Report
Multilevel Sensor Report
Basic Set
Basic Set
Battery Report
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Length
Default
R/W
(Bytes)
Value
1
R/W
0
1
R/W
121
1
R/W
121
1
R/W
121
1
R/W
121
1
R/W
0
1
R/W
1
1
R/W
10
1
R/W
0
1
R/W
10
1
R/W
0
1
R/W
0
1
R/W
0
1
R/W
0
1
R/W
0
1
R/W
5
1
R/W
0
1
R/W
5
1
R/W
0
1
R/W
1
1
R/W
0
1
R/W
0
1
R/W
30
GROUP NAME
Lifeline
Temperature Reports
Humidity Reports
Temperature Driven Basic Sets
Humidity Driven Basic Sets
Battery Reports
The manufacturer has a policy of continuous data
improvement and it reserves the right to change design
and specifications without notice. We are committed to
using environmentally conscious print practices.
All trademarks referenced are the trademarks of their
respective owners. Z-Wave is a trademark of Z-Wave
Alliance.
Valid Values
0 = Do not send periodically; Range: 1–127 hours
121 = Disabled; Range: 15 – 120° F
121 = Disabled; Range: 15 – 120° F
121 = Disabled; Range: 15 – 120° F
121 = Disabled; Range: 15 – 120° F
0 = Disabled; 1-5 = Number of extra attempts sent every
minute after first send
0 = Celsius; 1 = Fahrenheit
Range: 1 – 200; Parameter is in tenths of degrees.
0 = Disabled; Range: 1-120 minutes
0 = Disabled; Range: 1 – 50; Parameter is in tenths of
degrees.
0 = Disabled; Range: 1-120 minutes
0 = Disabled; Range: 1–100%
0 = Disabled; Range: 1-100%
0 = Disabled; Range: 1-100%
0 = Disabled; Range: 1-100%
Range: 1-50%
0 = Disabled; Range: 1-120 minutes
0 = Disabled; Range: 1-30%
0 = Disabled Range: 1-120 minutes
Configuration Register Combinations:
1 = Enable Registers 2, 5, 12 15
2 = Enable Registers 2, 5, 13, 14
3 = Enable Registers 3, 4, 12, 15
4 = Enable Registers 3, 4, 13, 14
Range: -7 to 7° F
Range: -7% to 7%
Range: 0 - 60 minutes 0 = Disabled
Page - 4
MAX DEVICES
1
5
5
5
5
5
U.S.A. / Canada
(877) 288-7707
© 2021

Advertisement

loading