Trane ZSENS930AW00MA Installer's Manual page 3

Z-wave temperature & humidity sensor

Advertisement

REMOVING A ZSENS930
Table 4.
NOTE: This will work for both "Offline" and "Online" sensors and only ZSENS930 sensors may be removed this way. The Summary Table will also work.
STEP 1
Unassign the sensor
Follow steps 1
through 3 in Table 3
for the sensor(s) that
are to be removed.
Action
They must be
unassigned to be
removed.
Screen 5
NOTE: This sensor can be added to any Z-Wave network. It can also be added to a Trane or American Standard connected thermostat with a built in Z-Wave bridge then assigned as
an indoor temperature sensor (IDT) from the Service Menu.
SUMMARY OF SENSOR OPERATION
INSTALL BUTTON – Function Overview
• Press once to add or remove the sensor from a Z-Wave Network.
• Press and hold, approximately 10 seconds, until the STATUS LED starts
blinking to restore factory defaults.
• Press three times rapidly to send a "BATTERY_REPORT" and
"WAKE_UP_NOTIFICATION" (if installed on a network).
The sensor will stay awake for 30 seconds.
STATUS LED – Function following a button press:
The LED will give an indication for 30 seconds following a button press. In that
time the following will be seen:
• Continuous On: Device is enrolled on a Z-Wave Network.
• Slow Blinking: Device is not enrolled on a Z-Wave Network.
• Fast Blinking: Successfully added to or removed from a Z-Wave network.
ADD – Adding the sensor to an existing Z-Wave network
1. Set your home's Z-Wave Bridge into ADD Mode.
2. Press and release the INSTALL button on the sensor.
3. The Status LED will blink rapidly for 3 seconds when it has been added to
your Z-Wave network. Your bridge will also indicate that the sensor was
successfully added.
REMOVE – Removing the sensor from a Z-Wave network
1. Set your home's Z-Wave Bridge into REMOVE Mode.
2. Press and release the INSTALL button on the sensor.
3. The Status LED will blink rapidly for 3 seconds when it has been removed
from your Z-Wave network. Your bridge will also indicate that the sensor
was successfully removed.
FACTORY RESET
Factory Reset should be used only when the primary controller is missing or
otherwise inoperable. Press and hold, approximately 10 seconds, until the Status
LED starts blinking.
** FOR INDOOR USE ONLY **
STEP 2
Select the "Offline" sensor.
Once the sensor is in the "Available Sensors" list,
select the "Wireless" button and then select the sensor
to be removed. Use the serial number to verify the
device is the correct sensor.
NOTE: The selected sensor will be highlighted in blue.
STEP 3
Remove the sensor
Tap the "Remove" button
NOTE: If the sensor is "Online" you will
need to press the "INSTALL" button on
the inside of the sensor while "Waiting to
Remove Device".
Screen 6
TROUBLESHOOTING
SYMPTOM
CAUSE
Sensor fails
to add to
Out of range
the network.
(slow blinking
of the Status
LED & no
Improperly
pairing action
removed
seen on the
from network
bridge)
previously.
Sensor drops
Edge of
connection
range
intermittently
Button press
Button press
too fast or too
ignored
slow
Sensor
goes from
"Online" to
Sensor is
"Offline"and
enabled but
"Missing
offline (not
Sensor"
reporting).
alarm
TSO.001.00
is shown
"Low Battery"
Sensor is
alarm
reporting a
TSO.004.00
low battery.
SPECIFICATIONS
SIZE (INCHES): 3.25 X 2.0 x 0.60
WEIGHT:
0.25 LBS
STEP 4
Screen change
Select "Done". The sensor is no longer
included in the "Available Sensors" list.
(Screen 6)
NOTE: To return a sensor to the list you will
have to go through the steps of Table 1.
CURE
Add a Z-Wave repeating device (e.g. light
module/dimmer) at a location between the bridge
and sensor. First add the repeater to the network
following that device's instructions. Then try
to add the sensor to the network again at the
desired sensing location.
Remove the sensor from the network, follow the
steps in Table 3. Then add it back to the network.
Add a Z-Wave repeating device (e.g. light
module/dimmer) at a location between the bridge
and sensor.
Firm 1/2 second button press.
Change the batteries in the sensor.
Remove the offline sensor following the steps
from Table 3 then reinstall or add a new sensor.
Add a signal repeater.
Change the batteries in the sensor.
POWER: 2 X AAA Alkaline Batteries
Z-WAVE ZM5202,US 908.4 MHz
RF:
/ 916 MHz
Page - 3