Trane ZSENS930AW00MA Installer's Manual page 2

Z-wave temperature & humidity sensor

Advertisement

ADDING A ZSENS930
Table 1.
FIRST, FOLLOW STEPS ONE THROUGH THREE IN THE INSTALLATION TABLE.
STEP 4.1
Access the "Service Menu"
Select
Action
"Indoor Sensor Setup"
Button
ASSIGNING A ZSENS930
Table 2.
FIRST, FOLLOW STEPS 1 THROUGH 3 IN THE INSTALLATION TABLE
ON PAGE 1 AND ALL THE STEPS IN TABLE 1.
STEP 5.1
Select the newly added sensor on the right side of the Sensor Assignment screen
Select an
under the label "Available Sensors".
available
NOTE: The selected sensor will be highlighted in blue.
sensor
Screen 1
STEP 5.2
Once the sensor is selected "Assign" will illuminate
on the Navigation Bar. Select "Assign".
Assign the
sensor
Repeat until all needed sensors are assigned.
STEP 5.3
The list of assigned and averaged sensors on the left is now updated and the
Sensor
previously unassigned sensor is now included. (Screen 2)
is now
assigned.
Screen 2
STEP 5.4
Select "Done" to save and exit the Indoor
Sensor Setup screen.
After this step follow
NOTE: By default all sensors in the Assigned list are
Step 7 and 8 from Page-1
averaged together evenly. Up to four sensors may be used
if not already complete
to define the temperature of the conditioned space.
STEP 4.2
STEP 4.3
Put the stat in "Add" mode
Add the Z-Wave sensor
Stand where the sensor is to be
Select "Wireless Sensor"
installed and press and release the
and then on the next
button labeled "INSTALL" on the
screen select "Add"
interior of the sensor.
The STATUS LED will blink rapidly
for 3 seconds
STEP 4.4
On screen response
Text at top of the screen should change:
From: "Waiting to Add Device – Press and Hold to Cancel"
To: "Adding Device"
After the sensor is added, "Temperature Sensor added as Device [X]:
Sensor added successfully." should appear.
UNASSIGNING A ZSENS930
Table 3.
STEP 1
Select the sensor to be removed from the assigned sensor list. Use the serial
Select an
number to verify the device is the correct sensor.
assigned
NOTE: The selected sensor will be highlighted in blue.
sensor
Screen 3
Once an assigned sensor is selected "Assign" will change to
STEP 2
"Unassign" on the Navigation Bar.
Unassign
Select "Unassign".
the sensor
The list of assigned and averaged sensors is now updated and the previously
STEP 3
asssigned sensor is moved to the "Available Sensors" list. (Screen 4)
Sensor
NOTE: The order of sensors does not matter. By default the temperature values
is now
from all sensors are averaged together evenly to determine the temperature of
unassigned.
the conditioned space.
Screen 4
STEP 4
Select "Done" to save and exit the
Indoor Sensor Setup screen.
NOTE: The thermostat will not allow you to exit this screen without at least one
sensor assigned to the system.
Page - 2