Specifications; Ordering Information - Honeywell S89C Manual

Hide thumbs Also See for S89C:
Table of Contents

Advertisement

------------------------------------------------ ---------- IMPORTANT------------------------------------------------------------------
THE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOL­
ERANCES. THEREFORE, THIS UNIT MAY NOT MATCH THE LISTED SPECIFICATIONS EXACTLY. ALSO,
THIS PRODUCT IS TESTED AND CALIBRATED UNDER CLOSELY CONTROLLED CONDITIONS, AND SOME
MINOR DIFFERENCES IN PERFORMANCE CAN BE EXPECTED IF THOSE CONDITIONS ARE CHANGED.
MODELS: See Table 1.
NO.
IGNITION
TRIALS
MODEL
1
S89C
S89D
1
3
S89G
3
S89H
1
S89J
1
S890C
S890D
1
3
S890G
3
S890H
S890J
1
a Ignition activation period (IAP) is the time both the igniter and the gas control are powered following warmup. The gas
control remains open 0.75 sec. min. after igniter turns off to allow flame sensing.
WHEN PURCHASING REPLACEMENT AND MODERNIZATION PRODUCTS FROM YOUR TRADELINE
WHOLESALER OR YOUR DISTRIBUTOR, REFER TO THE TRADELINE CATALOG OR PRICE SHEETS FOR
COMPLETE ORDERING NUMBER, OR SPECIFY—
1. Order number.
2. Lockout tim ing.
3. Leadwires, if desired.
IF YOU HAVE ADDITIONAL QUESTIONS, NEED FURTHER INFORMATION OR WOULD LIKE TO COMMENT
ON OUR PRODUCTS OR SERVICES, PLEASE WRITE OR PHONE:
1. YOUR LOCAL HONEYWELL RESIDENTIAL SALES OFFICE (CHECK WHITE PAGES OF YOUR PHONE
DIRECTORY).
2. RESIDENTIAL DIVISION CUSTOMER SERVICE
HONEYWELL INC., 1885 DOUGLAS DRIVE NORTH
MINNEAPOLIS, MINNESOTA 55422-4386 (612) 542-7500
IN CANADA— HONEYWELL LIMITED/HONEYWELL LIMITEE, 740 ELLESMERE ROAD, SCARBOROUGH,
ONTARIO M1P 2V9. INTERNATIONAL SALES AND SERVICE OFFICES IN ALL PRINCIPAL CITIES OF THE
WORLD.

SPECIFICATIONS

TABLE 1—HOT SURFACE IGNITION MODULES
IGNITER/
LOCKOUT
SENSOR
TIMING
TYPE
4, 6,11 or 15 sec.
Combination
nom., as ordered
Separate
Combination
Separate
4 sec. nom.
Combination
6 sec. nom.
4, 6,11 or 15 sec.
Combination
nom., as ordered
Separate
Combination
Separate
4 sec. nom.
Combination
6 sec. nom.

ORDERING INFORMATION

4. Molex plug for vent damper connection, If required.
5. Other components as required.
IGNITION
ACTIVATION
PERIOD®
Not
special
IAP model.
2 sec. max.
4 sec. max.
Not
special
IAP model.
2 sec. max.
4 sec. max.
2
PREPURGE
TIMING
None
30 sec. min.
(continued on page 3)