Snap the orifice stem back in place in this position in-
5.
serting it into the indent in the conversion cap
Insert the hexagon cap back into the regulator and
6.
tighten, do not over-tighten.
IMPORTANT: Attach the metallic sticker included with
7.
the LP conversion kit to the bottom of the appliance as
shown. This sticker provides notice that the appliance
has been converted for use with LP gas. It should be lo-
cated near the appliance rating plate.
→  "Rating plate location", Page 18
Note: If you change the type of gas back to natural gas
at a later point, remove the sticker.
5.2 Replacing the orifices
Remove all burner grates, burner caps and burner
1.
bases.
Remove the natural gas orifices and replace them with
2.
LP orifices using a 7 mm socket wrench. See burner
chart →  Page 17 .
For ease of installation use a small piece of tape and
insert it in the socket wrench to prevent the orifice
from falling out.
It is important to make sure that the orifices do not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
Normal burner with one orifice
⁠ .
Double burner, first orifice
Double burner, second orifice
Fasten the orifices.
3.
Save the orifices removed from the appliance for future
4.
use.
5.3 Adjusting the gas valves
Turn the control knobs to position off.
1.
Pull off the control knobs.
2.
Remove the screws at each burner.
3.
Conversion to LP gas en-us