A WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.

Recommended Grounding Method

This portable air conditioner must be grounded. This
portable air conditioner is equipped with a power supply
cord with a three-prong grounding plug. The cord must
be plugged into a mating, grounded three-prong outlet,
grounded in accordance with all local codes and
ordinances. If a mating outlet is not available, it is the
customer's responsibility to have a properly grounded
three-prong outlet installed by a qualified electrical
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and conforms to the Nation Electrical
Code,ANSI/NFPA 70-last edition,and all local
codes and ordinances.
Copies of the standards listed may be obtained from:
Nation Fire Protection Association
1 Batterymarch Park
Quincy,Ma 02169-7471
www.nfpa.org
NOTE:
The flexible exhaust hose allows placement of the air
conditioner at least 20" from window or door.
Confirm you are using the correct size air conditioner for
the space to be cooled, per sizing recommendations, below:
Area to be cooled
DOE Capacity needed(BTUs)
250 sq ft.
Up to10'x 25' Room
Up to 15'x 20' Room
300 sq ft.
Upto10'x35'Room
350 sq ft.
Up to 20' x 20' Room
400 sq ft.
Upto 10'x45' Room
450 sq ft.

Electrical Requirements

NOTE:

Location Requirements

5,500/6,000
6,500/7 ,000
7,500/8,000
8,500/9,000
9,500/10,000
5
Wiring requirement
115 V (103.5 min. to 126.5 max.)
15 A time-delay fuse or circuit breaker
Power Supply Cord
(dOlr
=
A.Test button
B.Reset button
Your air conditioner's device may differ from the one shown.
This room air conditioner is equipped with a power supply cord
required by UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is crushed, the
electronics detect leakage current and power will be
disconnected in a fraction of a second.
To test your power supply cord:
1. Plug power supply cord into a grounded 3prong outlet.
2. Press RESET (on some devices, a green light will turn on).
3. Press TEST (listen for click; Reset button will trip, and on
some devices, a green light will turn off).
4. Press and release RESET (listen for click; Reset button will
latch, and on some devices, a green light will turn on). The
power supply cord is ready for operation.
NOTE:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.
Match BTUs to room use and location:
NOTE:
Shaded room reduce to next smaller size
Sunny room increase to next larger size
For kitchens, increase to next larger size
A