200 amp clamp meters

Advertisement

To Measure AC Current:
1. Set the rotary switch to the appropriate AAC range.
2. With the jaws closed, separate one wire from a bundle using
the long fixed jaw.
3. Slide the wire to the corner where the two jaws meet, then
open the jaws to let it in.
4. Measure the current in only one wire at a time.
AC & DC Volts
AC Voltage
Range Resolution
Max
Accuracy
Models
Display
2000mV
1mV
1999
±(1.2%+3)
61-702
200V
0.1V
199.9 ±(1.2%+3) 61-700, 61-701,
61-702
600V
1V
600
±(2%+5) 61-700, 61-701
750V
1V
750
±(2%+5)
61-702
Frequency response: 50Hz - 500Hz; ±(2%+5) 500Hz - 1KHz;
50Hz - 500Hz on 600V and 750V ranges.
7
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
DC Voltage
Range Resolution
Max
Accuracy
Models
Display
200mV
0.1mV
199.9 ±(0.5%+1)
61-700
2000mV
1mV
1999
±(0.5%+1) 61-700, 61-702
20V
10mV
19.99 ±(0.5%+1)
61-701
200V
0.1V
199.9 ±(0.5%+1) 61-700, 61-702
600V
1V
600
±(0.5%+1)
61-700
1000V
1V
1000
±(0.5%+1)
61-702
To Measure Voltage:
5. Plug the black test lead into the COM port and the red test
lead into the + port.
6. Set the rotary switch to appropriate VAC or VDC range.
7. Connect the meter in parallel with the load or circuit.
8. Measure the voltage
Frequency
Range
Resolution
Max
Accuracy
Display
2k~40kHz
1Hz
40.0
±(0.1%+3)
8
Model
61-700,
61-701

Advertisement