Test Equipment Depot 8901 Operation Manual

Digital anemometer

Advertisement

Quick Links

99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Advertisement

loading

Summary of Contents for Test Equipment Depot 8901

  • Page 1 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com...
  • Page 3 FEATURES A. Measuring Air Velocity (Single point) Feet per Minute (FPM). B. Continuous Moving Average. C. MIN/MAX/AVG reading on a single point. D. Air Velocity average for multiple points . E. Non Sleep Mode(Bypass auto power off). F. Default setting ( Imperial/ Metric) G.
  • Page 4 FRONT PANEL DESCRIPTION BUTTON / DISPLAY 1.ON/OFF. Power on or off . 2.HOLD SET/SAVE. Freezs the reading. Adjust the digit to the value needed. 3.SEL/AVG ,NXT DGT-> MULTI-P. AVERAGE . Display the average of all the measurements. Select the next digit for editing.
  • Page 5 INDICATORS Air velocity measurement. 1.vel. 2.FLOW. Air Flow/Air volume. 3.AREA. Free area degault setting. 4.Hold. Freezs the reading. Feet per minute.(imperial) 5.ft/m. Meter per second.(metric) Feet square.(imperial) 6.ft . meter square.(metric) 7.m . Cubic feet per minute. 8.cfm. Cubic meter per second. 9.cms.
  • Page 6 A. MEASURING AIR VELOCITY (SINGLE POINT) FEET PER MINUTE (FPM) 1. Press the ON/OFF button and turn meter on. Meter will show full display when first powered on in 5 seconds. (See Fig.1) 2. Unit is ready for use when LCD display shows "vel"...
  • Page 7 C. MIN/MAX/AVG READING ON A SINGLE POINT To obtain MIN/MAX/AVG readings on a single point. 1. Power unit ON. 2. Place sensor in front of air flow source. 3. Press MN/MX REC SINGLE-P key. The unit will begin to record the readings.
  • Page 8 Press the HOLD key before removing the unit from the air source.Press the MIN/ MAX REC SINGLE-POINT key to view the stored data which will appear in the following order : Instantaneous measurement Minimum Maximum Average To clear the current MIN/MAX average readings, turn off the power or press and hold MN/MX key until unit beeps twice, then release.
  • Page 9 Hold Fig.5 Hold Fig.5-1 Repeat this process until all desired points have been measured and recorded, A maximum of 8 points may be recorded at one time. 3. Once all measurements have been recorded press SEL/AVG key. The unit will display the average air velocity reading and number of points measured.
  • Page 10 F. HOW TO CHANGE THE DEFAULT SETTING/IMPERIAL TO METRIC Vice Versa(METRIC TO IMPERIAL) The default measuring units can be changed by following the steps below. The unit should be turned off before commencing. 1. Press and hold the SEL/AVG key, then press the ON/OFF key once to turn the unit on.
  • Page 11 3. Press the MN/MX REC key, the LCD should display "S" (See Fig.10) . Then press the HOLD key. The LCD display 2400 or 1200 (pre-setting). (If Baud rate change is needed, please refer to step G.1) (See Fig.11) Fig.10 Fig.11 4.
  • Page 13 H. AUTO POWER OFF The unit will turn off automatically after 20 minutes to save the battery. Press ON/OFF and HOLD button to disable Auto Power Off function. I. DIRECT MEASURING OF AIR FLOW (SINGLE POINT) CFM Air Velocity measurement is calculated by multiplying the air velocity readings by the free area dimensions.
  • Page 14 TO CLEAR MEMORY OF CURRENT MULTI- POINT AVERAGE READINGS. Press and hold SEL/AVG key until unit beeps twice, then release. Unit must be in velocity/FPM mode in order to clear current average readings. J. TO OBTAIN AIR FLOW (CFM) AVERAGE FOR MULTIPOINTS Simply complete steps 1~3 in D.
  • Page 15 We would suggest to set the free area dimension before you start measuring the air velocity so after you measure the air velocity, you can jump to the air flow mode to view the cubic feet per minute without further changing the free area dimension.
  • Page 16: Trouble Shooting

    TROUBLE SHOOTING ? LOW BATTERY When the reading of display is flashing, or no display , please change the 9 volt battery in the meter . Replace battery procedure: Remove the screw from the lower back of the meter. Lift the panel out and remove the battery .Reverse the process to install a new battery and replace the cover .
  • Page 17: General Specification

    GENERAL SPECIFICATION Resolu- SPECIFICATIONS Accuracy tion 2%FS 80-6900 ft/min Airflow Range 0.4-35 m/sec 0.01 2%FS -10 C to 50 C 0.6 C Temperature +14 F to 122 F 1.0 F Battery Life 100 Hours Display Type LCD Display Size 37mm x 42mm(1-1/4" x 1- 5/8") Max Reading 9999 181mm(L)x71mm(W)x38mm(D) Dimensions...
  • Page 18 Connection procedures: 1.Plug the optional accessory RS232 cable onto the DC jack port ( at the right side of the meter) 2.Instert the D-sub 9P type connector onto computer's Com.1 or 2 port or..3.Start to set up RS232 software by inserting the CD-ROM or Floppy diskette.
  • Page 19 RETURN AUTHORIZATION Authorization must be obtained from the supplier before returning items for any reason . When requiring a RA (Return Authorization) , please include data regarding the defective reason, the meters are to be returned along with good packing to prevent any damage in shipment and insured against possible damage or loss .