4 Installation
Step 8: Mount indoor unit
If you installed new connective piping to the
outdoor unit, do the following:
1. If you have already passed the refrigerant piping
through the hole in the wall, proceed to Step 4.
2. Otherwise, double-check that the ends of the
refrigerant pipes are sealed to prevent dirt or
foreign materials from entering the pipes.
3. Slowly pass the wrapped bundle of refrigerant
pipes, drain hose, and signal wire through the
hole in the wall.
4. Hook the top of the indoor unit on the upper
hook of the mounting plate.
5. Check that unit is hooked firmly on mounting
by applying slight pressure to the left and
right-hand sides of the unit. The unit should
not jiggle or shift.
6. Using even pressure, push down on the bottom
half of the unit. Keep pushing down until the
unit snaps onto the hooks along the bottom of
the mounting plate.
7. Again, check that the unit is firmly mounted
by applying slight pressure to the left and the
right-hand sides of the unit.
If refrigerant piping is already embedded in the
wall, do the following:
1. Hook the top of the indoor unit on the upper
hook of the mounting plate.
2. Use a bracket or wedge to prop up the unit,
giving you enough room to connect the
refrigerant piping, signal cable, and drain hose.
Split Type Air Conditioner / User Manual
3. Connect drain hose and refrigerant piping
(refer to Refrigerant Piping Connection section
of this manual for instructions).
4. Keep pipe connection point exposed to perform
the leak test (refer to Electrical Checks and
Leak Checks section of this manual).
5. After the leak test, wrap the connection point
with insulation tape.
6. Remove the bracket or wedge that is propping
up the unit.
7. Using even pressure, push down on the bottom
half of the unit. Keep pushing down until the
unit snaps onto the hooks along the bottom of
the mounting plate.
Keep in mind that the hooks
on the mounting plate are
smaller than the holes on the
C
back of the unit. If you find that
you don't have ample room to
connect embedded pipes to
the indoor unit, the unit can be
adjusted left or right by about
30-50 mm (1.18-1.95in),
depending on the model.
30-50mm
30-50mm (1.18-
(1.18-1.95in)
1.95in)
Move to left or right
Move to left or right
Wedge
30-50mm (1.18-
30-50mm
(1.18-1.95in)
1.95in)
27 / 116 EN