1.4.4. Operation of ShPS-12 mod.10, ShPS-12 mod.11, ShPS-12 mod.12 under S2000M Rev.02
Control Panel
1.4.4.1. For small facilities with an addressable fire alarm system where it is no need to integrate
several control panels into a network connected to Orion Pro software, it is reasonable to use an
S2000M rev.02 control panel. To operate an S2000M rev.02 with RS-485 interface redundancy
protection, both interfaces should be connected to separate interfaces of the BK-12-RS485. For more
detail information, please refer to S2000M Rev.02 User's Manual, which can be found at
www.bolid.ru
in the section PRODUCTS.
1.4.5. Updating Firmware
1.4.5.1. ShPS-12 boxes support updating their firmware in field over the RS-485 interface by
means of the Orion_prog utility ("Firmware Update"). The last version of this program is available
online at the address of http://bolid.ru.
WARNING!
During updating the MIP-12 disables output voltage
1.4.5.2. For ShPS-12 mod.10, ShPS-12 mod.11, ShPS-12 mod.12 firmware versions can be
updated in field over the RS-485 interface by means of the Orion_prog utility ("Firmware Update").
The last version of this program is available online at the address of http://bolid.ru. To switch the BK-
12-RS485 to the programming mode, please close the jumper circuit ХР5 ("PROG") on the board of
the BK-12-RS485. The programming mode is indicated by two board LEDs' blinking once per second.
Only one of the separate RS-485 interfaces is used for updating.
WARNING!
Upon entering the programming mode the BK-12-RS485 occupies the address of
127. So, for correct operation this address should be free

1.5 Measuring Instruments, Tools, and Accessories

While mounting, commissioning, and maintaining ShPS-12, please use the instruments, tools, and
accessories shown in Table 4.
Instrument
Digital multimeter
Flat head insulated screwdriver
Cross slot insulated screwdriver
Side-cutting pliers
Pliers
1.6 Marking and Sealingе
Every ShPS-12 box has a marking applied to its enclosure.
The marking contains the name of the device, its decimal number, factory number, the year and
quarter of production, and conformity marks.
12
AC/DC voltage up to 500 V, AC/DC current up to 10 A, re-
sistance up to 20M Ohm
SL2.5 х 75 mm
PH1 х 75 mm
160 mm
160 mm
Specifications