U Sing The Multimeter - Maxwell 25700 User Manual

Automatic multimeter - non-contact voltage detection
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
EN
User Manual
r
esistance
Measuring range
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
60 MΩ
a
ccUracy
Measuring range
6 nF
60 nF
600 nF
6 µF
60 µF
600 µF
6 mF
60 mF
f
reqUency
Measuring range
10 Hz ~ 100 kHz
1 MHz
20 MHz
Resolution
Accuracy
0.1 Ω
±(1,3% + 5d)
1 Ω
±(1,3% + 5d)
10 Ω
±(1,0% + 5d)
100 Ω
±(1,0% + 5d)
1 kΩ
±(1,0% + 5d)
10 kΩ
±(1,5% + 5d)
Resolution
Accuracy
1 pF
± (3.0% + 5d)
10 pF
± (3.0% + 5d)
100 pF
± (3.0% + 5d)
1 nF
± (3.0% + 5d)
10 nF
± (3.0% + 5d)
100 nF
± (3.5% + 5d)
1 µF
± (5.0% + 6d)
10 µF
± (10.0% + 8d)
Accuracy
± (1.0%+5d)
± (3.0%+5d)
± (4.0%+10d)
c
ontrols
MP 25700
2
1
VC803
deactivate these functions, press and hold the button again.
3
Function toggle button: Briefly press the button once
and select (NCV) or (CAP) or (Hz). Press and hold this button
for approx. 2 seconds to exit the function mode and enter
the voltage / resistance auto detection mode.
U
sing tHe MUltiMeter
DC / AC voltage measurement (> 1 V)
1. Measurement is only possible if the voltage is greater
than 1 V.
2. Connect the red instrument cable to the appropriate
socket, then connect the black instrument cable to the
„COM" socket.
3. DC or AC voltage measurement is automatic.
4. Touch the probes to the appropriate point on the test
circuit to measure the voltage.
5. Read the measured voltage from the display.
Resistance measurement
1. Connect the red wire to the appropriate socket, then
connect the black instrument cable to the „COM" socket.
2. The resistance is measured automatically.
3. Touch the probes to the appropriate point on the test
circuit to measure the resistance of the circuit.
4. Read the measured resistance from the display.
Continuity test
1. Connect the red instrument cable to the appropriate
socket, then connect the black instrument cable to the
„COM" socket.
2. The continuity test measurement is performed
automatically.
1
Power button: Briefly
press this button to turn
on and the device will
automatically
voltage / resistance auto
detection mode. (Voltage,
resistance, or current can
be measured directly.) To
turn off, press and hold
3
this button for at least
2 seconds.
2
„H" button: Press once
to keep the current value
on the display. „H" appears
on the display. To clear
the
value,
press
button again.
Backlight / Flashlight:
Press and hold for at least
2 seconds to backlight
the display and turn on
the flashlight function. To
start
in
the

Advertisement

Table of Contents
loading

Table of Contents