Specification - Maxwell 25700 User Manual

Automatic multimeter - non-contact voltage detection
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
p
arts of display
hFE
AUTO
OUT
AUTO – Automatic measuring
– High voltage warning
– Dangerous voltage warning
hFE – Transistor testing
– Diode test
– Continuity test
– Battery charge
MIN / MAX - Measurement range
– Data hold
– DC current sign
– AC current sign
– Rectangular impulse
Unit of measurement (%,°C, °F, MK, Ohm, Hz, m, AV, nF)
g
eneral tecHnical paraMeters
Display
Maximum characteristic
Range
Sampling
Low power indication
True RMS
Data hold
Backlight
Flashlight
Automatic shutdown
Operating temperature
Storage temperature
Dimensions
MIN MAX
%
Mk Hz
m μ
AVnF
4 digits, LCD
6000
Automatic
About 3x in one second
0 ºC - 40 ºC, <75%
humidity
-20 ºC - 60 ºC, <85%
humidity
187 x 66 x 32 mm
Continuity
NCV
s
pecification

Specification

Accuracy measurements were measured one year after
calibration at a temperature between 18 ºC and 28 ºC and
a relative humidity of <75%. Format: ± (% measured value
+ digit value)
ac v
oltage
Measuring range
6 V
60 V
600 V
Frekvencia
Note: The device malfunctions, burning of
not measure voltages above 600 V in order to
dc v
oltage
Measuring range
6 V
60 V
600 V
Note: The device malfunctions, burning of
not measure voltages above 600 V in order to
ac c
Urrent
Measuring range
1 A
10 A
Frequency range
dc c
Urrent
Measuring range
1 A
10 A
Frequency range
EN
User Manual
Resolution
Accuracy
0.001 V
± (1%+5d)
0.01 V
± (1%+5d)
0.1 V
± (1%+8d)
40 Hz ~ 1 kHz
prevent!
Resolution
Accuracy
0.001 V
± (0.5%+5d)
0.01 V
± (0.5%+5d)
0.1 V
± (0.8%+5d)
prevent!
Resolution
Accuracy
1 mA
± (1.2%+6d)
10 mA
± (1.2%+6d)
40 Hz ~ 1 kHz
Resolution
Accuracy
1 mA
± (1.0%+5d)
10 mA
± (1.0%+5d)
40 Hz ~ 1 kHz

Advertisement

Table of Contents
loading