  • Page 1 IMC100-2T1F-1D Industrial Media Converter User Manual Version 01 Issue Date: 2019-01-28 Industrial Ethernet Communication Solutions Expert 3onedata Co., Ltd.
  • Page 2 Purchased product, service or features should be constrained by 3ondedata commercial contracts and clauses. The whole or part product, service or features described in this document may beyond purchasing or using range. 3onedata won't make any statement or warranty for this document content unless any other appointment exists.
  • Page 3 3onedata Co., Ltd. 3/B, Zone 1, Baiwangxin High Technology Industrial Park, Song Bai Road, Headquarter address: Nanshan District, Shenzhen, 518108, China Technology support: tech-support@3onedata.com Service hotline: +86-400-880-4496 E-mail: sales@3onedata.com Fax: +86-0755-26703485 Website: http://www.3onedata.com...
  • Page 4: Preface

    Represent the words click to achieve hyperlink. Font color as: "Light blue". About This Chapter The "About This Chapter" section provides links to each section and corresponding principles / operating chapters in this chapter. Icon Convention Format Description 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 5 Configuration, operation, or tips for device usage. Pay attention to the operation or information to ensure success device configuration or normal working. Revision Record Version NO. Revision Date Revision Description 2019-01-18 Product release 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 6: Table Of Contents

    OGIN ETTINGS FAQ ............................22 ....................22 IGN IN ROBLEMS ..................22 ONFIGURATION ROBLEM ....................23 NDICATOR ROBLEM MAINTENANCE AND SERVICE ..................25 ....................25 NTERNET ERVICE ....................25 ERVICE OTLINE ................26 RODUCT EPAIR OR EPLACEMENT 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 7: Log In The Web Interface

    The switch default management as follows: IP Setting Default Value IP Address 192.168.1.254 Subnet Mask 255.255.255.0 While configuring the switch via Web: Before remote configuration, please make sure the route between computer and  3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 8 In windows system, if user adopts the advanced configuration function of IP address and accesses the switch device via setting IP dummy address, the following managed functions can't be achieved: IEEE 802.1x polling. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 9: Log In The Web Configuration Interface

    Step 6 End. After login in successfully, user can configure relative parameters and information according to demands. Notes: After login in the device, modify the switch IP address for usage convenience. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 10: System Status

    Basic Infor interface as follows: The main element configuration description of Basic Infor interface: Interface Element Description Name The device name. Note: This item can be modified and input up to 30 characters. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 11 DNS server address acquisition for the device IP address. IP Address Configure IP address of the device. Notes: Default configured IP address is 192.168.1.254. Subnet Mask Configure subnet mask of the device. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 12: Port Infor

    Open in order: "Main Menu > System Config > Port Infor". Interface Description Port Infor interface as follows: The main element configuration description of Port Infor interface: Interface Element Description Port Display the device port number. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 13  Note : When the speed/duplex is self-adaption mode, the port would adapt to port speed/duplex mode automatically. Support two kinds of Flow Control State: Flow Control Enable  Disable  3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 14: System Config

    The port status doesn’t support disabling two copper ports at the same time.  Operation Path Open in order: "Main Menu > System Config > Port Setting". Interface Description Port setting interface as follows: 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 15 When the speed/duplex is “Auto”, the port would adapt to port speed/duplex automatically. Support two kinds of Flow Control State: Flow Control Enable  Disable  Jumbo Frame Support two kinds of Jumbo Frame State: Enable  Disable  3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 16: Vlan

    On the page of "COM Settings", user can implement serial port parameter configuration and work mode configuration. Operation Path Open in order: " Main Menu > System Config > COM Settings". 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 17 The length of serial port data frame. Its value range is 1~1024 byte(bytes) Data Bits (bits) Select data bits of corresponding serial number. Options include: 7 bits;  8 bits.  3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 18 DisconTimeOut If no activity happens within the specified time, the system would send connection detection message to check whether the connection is valid. If it has sent successive probe packet 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 19: Ip Filtering

    On the “IP Filtering” page, user can limit the host IP address and subnet mask that user wants to access or connect via setting access rule. Operation Path Open in order: “Main Menu > Safety Management > IP Filter”. Interface Description IP filter interface as follows: 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 20: Mac Filtering

    IP Address Set decimal IP address in filtering rules, for example “192.168.1.61”. Subnet Mask Set decimal subnet mask in filtering rules, for example “255.255.255.0”. 3.5 MAC Filtering Function Description 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 21 Forbidden: forbid to access the MAC address and subnet  mask that user has set. MAC Address Set the six-byte, hexadecimal MAC address in filtering rules, for example “00-22-6F-03-BD-52”. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 22: Relay Warning

    Configure the port alarm function. Options as follows: Enable;  Disable.  Note After enabling port alarm, when port is in abnormal status, such as connection or disconnection, the device will output a signal to hint 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 23: Storm

    Storm interface as follows: Main elements configuration description of storm interface: Interface Element Description Storm Enable or disable storm suppression function. Max-speed Choose the largest speed of the port. Options are: 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 24 User Manual      Limited type Choose limit type. Options are: Broadcast  Unknown Multicast  Unknown Unicast  3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 25: System Tools

     Upload and download configuration files;  System upgrading.  Operation Path Open in order: "Main Menu > System Tools >System File Management". Interface Description System File management interface as follows: 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 26: Login Settings

    On the “Login Settings” page, user can configure the login name and password of logging in to WEB configuration page and other parameter information. Operation Path Open in order: “Main Menu > System tools > User Password”. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 27 Login name setting of WEB configuration interface. Password Login password setting of WEB configuration interface. Note: The password should a combination of letters that less than 16 bytes. Confirm password Confirm password. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 28: Faq

    When some ports on the switch are impassable, it may be network cable, network adapter and switch port faults. User can locate the faults via following tests: Connected computer and switch ports keep invariant, change other network cable; 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 29: Indicator Problem

    Not connected to the power socket; troubleshooting, connected to the power socket. Interface rate doesn't match the pattern; troubleshooting, examine whether the device transmission speed matches the duplex mode. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 30 Network cable is disturbed by static electricity or surge; Troubleshooting, change the shielded cable or install a lightning protector. High and low temperature influence; troubleshooting, check the device temperature usage range. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 31: Maintenance And Service

    Users using our company products can call technical support office. Our company has professional technical engineers to answer the questions and help solve the products or usage problems ASAP. Free service hotline: +86-400-880-4496 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 32: Product Repair Or Replacement

    According to the company's handling procedure, customers should negotiate with our company's technical staff and salesmen to complete the product maintenance, replacement or return. 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.
  • Page 33 User Manual 3onedata Co., Ltd. Headquarter address: 3/B, Zone 1, Baiwangxin High Technology Industrial Park, Song Bai Road, Nanshan District, Shenzhen Technology support: tech-support@3onedata.com Service hotline: +86-400-880-4496 Official Website: http://www.3onedata.com 3onedata proprietary and confidential Copyright © 3onedata Co., Ltd.