Functioning anomalies.

No ignition block
The ignition transformer carries out the discharge.
a
The wiring between the ignition electrodes and P.C.B. is OK
230 VAC are present on clamps 1-2 of connector X7.
The connector and relative wiring between the gas valve and the
P.C.B. are OK.
b
The gas valve main coils are OK.
Replace the gas valve.
N.B.: before replacing the valve always check that there is sufficient dynamic pressure in gas input and that the adjustment screws of the minimum and
maximum heat output are correctly adjusted.
The electrode detects a direct current of 6-8 μA during the burner
ignition phase.
c
Replace the P.C.B.
Over-temperature safety thermostat block.
The wiring between the safety thermostat and P.C.B. is OK.
a
Check/replace the safety thermostat. If the anomaly should persist, replace the P.C.B.
The pump operates correctly.
N.B.: make sure that the pump operates at maximum speed.
Any heating system zone valves or intercepting valves are open.
b
The NTC flow probe is OK (10 kΩ a 25°C).
Check/clean/replace the main exchanger.
Flue pressure switch anomaly
230 VAC are present on clamps 6-7 of the connector X10 on the
P.C.B.
a
230 VAC are present on the fan clamps.
Replace the fan.
STEMkW Special ed 01/08
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
LED n°6 flashing
No
Replace the P.C.B.
Restore/replace the ignition electrodes and relative cables.
No
No
Replace the P.C.B.
No
Restore the electric connection/replace the wiring.
Where possible, replace the gas valve main coils.
No
Replace detection electrodes and/or relative wiring.
No
LED n°7 flashing
No
Restore the electric connection/replace the wiring.
No
See section B
Restore circulation in the heating system by acting on the closed devices
and also check:
- the correct functioning of the boiler by-pass;
- the opening times of any zone valves (on requirement it is possible to
No
delay ignition of the burner by acting on the "delay heating ignition from
TA or CAR requests" parameter of the boiler);
- the correct functioning of any thermostatic valves.
No
Replace the NTC probe.
LED n°8 flashing
No
Replace the P.C.B.
No
Restore the electric connection/replace the wiring.