Functioning Anomalies With Manual Rearm - Immergas VICTRIX 50 Instruction And Warning Booklet

Hide thumbs Also See for VICTRIX 50:
Table of Contents

Advertisement

38
Hysteresis detection in DHW mode ON
39
Hysteresis detection in DHW mode OFF
Heating time (multiply the value shown on the display
40
by 10.2 to achieve the time value in seconds)
DHW time (multiply the value shown on the display
41
by 10.2 to achieve the time value in seconds)
Timing in the passage from DHW functioning to CH
42
functioning mode (multiply the value shown on the
display by 10.2 to achieve the time value in seconds)
43
DHW priority maximum time
44
Cascade address
45
Type of control for CH system
46
Type of DHW system
47
Manual fan speed
48
PWM signal level for pump
49
PWM signal level for pump
50
PWM signal level for pump
51
PWM hysteresis
53
Low/O cycle and pump cycle
Minimum number of revs for pressure switch (in
54
hundreds)
55
Boiler minimum maintenance temperature
56
CH ramp or CH and DHW

3.4 FUNCTIONING ANOMALIES WITH MANUAL REARM.

Code
E 00
Flame presence not allowed
E 02
Ignition block
E 03
Gas valve supply error
E 05, E 11, E 15,
E 16, E 17, E 44,
Internal block (electronic)
E 60
E 04
Non volatile block (occurs in the case of block and power cut)
E 06
Fault in P.C.B. input detected
E 07
Gas valve relay error
0°C
-5°C
0 seconds
0 seconds
1 (0=passage with
burner on)
1 min. (0=domestic
hot water priority
always)
NOT ACTIVE
00 = room thermostat
01 = external probe
02 = 0-10 V Power
03 = 0-10 V Temperature
00 = Instant with probe
01 = Instant without probe
02 = Storage tank with probe
03 = Storage tank without probe
-1 = O
0%
1
10
15
1°C
x0 = O
Low/O cycle
x1 = On
0x = Normal central heating pump and
DHW cycle
5
0°C
0 = heating only
1 = heating+DHW
Description
27 - IE
30°C
5
30°C
0
30
18
0
30
0
30
0
120 min.
0
00
02
-1
100%
NOT ACTIVE (32)
4
NOT ACTIVE (15)
50
NOT ACTIVE (20)
50
NOT ACTIVE (02)
10°C
00
70
NOT ACTIVE (5)
0°C
80°C
0
Remedy
Check detection electrode
Check P.C.B.
Check gas valve
Check P.C.B.
Check electrodes position
Check ame signal at minimum, greater than 6 µA
Check gas valve/P.C.B.
Replace the P.C.B.
Check P.C.B.
Replace the P.C.B.
Check cause of block
Check P.C.B.
Replace the P.C.B.
Check gas valve/P.C.B.
Replace the P.C.B.

Hide quick links: