Preventative Maintenance Schedule:

Every 40 to 200 Hours
o Check and clean air intake filter. Every 4 filter cleanings a new filter should be installed and
minimally every year.
o Blow dust and debris off outside of pump
Every 3000 Hours
o Grease bearings with pump running. Remove filter cover and place filter over direct inlet to
pump and start pump. Remove grease fitting covers and pump gun
25 times in each fitting
o Check Vanes for minimum width. Replace if necessary.
2.200/250/250SK – 41mm minimum width
2.400/500 – 60mm minimum width
o Inspect vanes for improper wear (cupping or uneven wear). Replace if necessary.