Troubleshooting:
o Vane breakage after commissioning.
o Vane breakage
End-Shield - contact

Vane Breakage

Rotor turns backwards. (Check the electrical connection!)
Pump has been stored in very humid ambient.
Swelling of vanes; corrosion on surfaces.)
Too many start/stops.
Limit 6 per hour.
Rotor turns backwards due to missing check valve.
Overload (Clogged filter cartridges).
Grease was not removed from the face of the end-shield causing the vane
to stick in the slots.
Non-Becker Vanes are used.
Vanes cupping due to overheating.
Blocked Relief valve.
Pump was not configured for altitude.
Too much discharge plumbing.
Rotor has swelled due to overheating and contacted the end-shields.
If you see signs of contact, call your Local Becker representative.
Rotor - contact
Cupping