Check the condition of the TSL fluid daily.
Change the TSL fluid if it becomes a gel, its color
darkens, or it becomes diluted with isocyanate.
Gel formation is due to moisture absorption by
the TSL fluid. The interval between changes
depends on the environment in which the
equipment is operating. The TSL fluid system
minimizes exposure to moisture, but some
contamination is still possible.
TSL fluid discoloration is due to continual
seepage of small amounts of isocyanate past
the pump packings during operation. If the
packings are operating properly, TSL fluid
replacement due to discoloration should not be
necessary more often than every 3 or 4 weeks.
To
To change
To
change TSL
change
TSL Fluid:
TSL
Fluid:
Fluid:
1. Follow
Pressure Relief Procedure, page
2. Lift the TSL fluid reservoir (R) out of the
bracket and remove the reservoir from the
cap. Hold the cap over a suitable waste
container and flush contaminated fluid
out of the lines by placing the strainer in
the new fluid and dispense contaminated
fluid through the return line into the waste
container.
3. Manually cycle the peristaltic pump (PP) in
the diagnostic screen until all contaminated
TSL fluid is removed from the system.
4. Drain the reservoir and flush it with clean
TSL fluid or replace it with a new reservoir.
5. When the TSL fluid system is flushed clean,
fill it with fresh TSL fluid.
54
Throat Seal
Seal
Throat
Seal
Fluid
Fluid
33.
6. Thread the reservoir onto the cap (H)
assembly and place it in the bracket.
7. Verify the TSL fluid pump is operating
correctly by feeling the pulsation in the
return hose during normal proportioner
pump operation.
Recycling and
and Disposal
Disposal
Recycling
Recycling
and
Disposal
End of of of Product
Product Life
Life
End
End
Product
Life
At the end of a product's useful life, recycle it in
a responsible manner.