ADJUSTMENT OF MINIMUM
LEVEL
To adjust the minimum level of the burners:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the control knob.
4.
With a thin screwdriver, adjust the by-
pass screw position.
A
A)
The by-pass screw
• If you change from natural gas G20 20
mbar (or natural gas G20 13 mbar
liquid gas, fully tighten the by-pass screw
in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
• If you change from natural gas G20 20
mbar to natural gas G20 13 mbar
do the by-pass screw about 1/4 of a
turn.
• If you change from liquid gas to natural
gas G20 13 mbar
screw about 1/2 of a turn.
• If you change from natural gas G20 13
3)
mbar
tighten the by-pass screw about 1/4 of a
turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the knob
from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
• Ground the appliance according to safe-
ty precautions.
• Make sure that the rated voltage and
type of power on the rating plate agree
3) only for Russia
3)
, undo the by-pass
to natural gas G20 20 mbar to
with the voltage and the power of the lo-
cal power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug, able to support the load
marked on the rating plate. The plug has
to be fitted in a correct socket.
• Any electrical component must be instal-
led or replaced by the Service Force
Centre technician or qualified service
personnel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to the
mains plug after installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extension cable, an adapter or a
multiple connection (risk of fire). Check
that the ground connection is in con-
formity with the standard and regulations
3)
) to
force.
• The power cable must be placed in such
a way that it does not touch any hot
part.
• Connect the appliance to the mains with
a device that lets to disconnect the ap-
pliance from the mains at all poles with a
3)
un-
contact opening width of minimum 3
mm, eg. automatic line protecting cut-
out, earth leakage trips or fuse.
• None of a parts of the connection cable
can not get a temperature 90 °C. The
blue neutral cable must be connected to
the terminal block label with "N". The
brown (or black) phase cable (fitted in
the terminal block contact marked with
"L") must always be connected to the
live phase.
REPLACEMENT OF THE
CONNECTION CABLE
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.