Download Print this page

Gira KNX Control 9 Client Operating Instructions Manual

Hide thumbs Also See for KNX Control 9 Client:

Advertisement

Quick Links

KNX
Control 9 Client, Control 9 KNX
Control 9 Client
Order No. : 2078 00
Control 9 KNX
Order No. : 2079 00
Operating instructions
1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled
persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect device before working on it. At the same
time, take into account all circuit breakers that supply dangerous voltage to the device.
Do not operate the device with sharp or pointed objects. The touch-sensitive surface
could be damaged.
Do not use any sharp objects, acids or organic solvents for cleaning. Device can be
damaged.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
82576732
Figure 1: Front view with frame
03.06.2016
1/11

Advertisement

loading

Summary of Contents for Gira KNX Control 9 Client

  • Page 1 Control 9 Client, Control 9 KNX Control 9 Client Order No. : 2078 00 Control 9 KNX Order No. : 2079 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock.
  • Page 2 Control 9 Client, Control 9 KNX Figure 2: Front view without Design frame (1) Design frame (2) Touchscreen surface (3) Bracket for Design frame (4) Holes for wall fastening (5) Slot for SD memory card (6) On/off push-button (7) Service interface (8) LED Prog.
  • Page 3: Operation

    Windows XP Professional in a memory-optimised version. All the components required for the device function are preinstalled. Additional drivers or programs, e.g. Gira software package QuadClient, can be installed at any later time. 4 Operation Cleaning the touchscreen The touchscreen requires regular cleaning in order to guarantee the optimum touch sensitivity.
  • Page 4 When delivered, the device logs in automatically with the username Control and the password gira . Carrying out a reset If the panel can no longer be operated, e.g. after a program has crashed, then the device can be reset and switched off.
  • Page 5 Control 9 Client, Control 9 KNX In the information area of the taskbar, system programs are preinstalled using the symbol (28), e.g. for setting the screen brightness. Control 9 KNX: Recalling Windows user interface After switching on, the KNX device starts the KNX application immediately. The display and operating elements of the KNX application are controlled via its own graphic user interface.
  • Page 6 Control 9 Client, Control 9 KNX 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before working on the device, disconnect all the corresponding miniature circuit breakers.
  • Page 7 Control 9 Client, Control 9 KNX Figure 5: Ventilation openings, front side Ensure sufficient cooling. Do not cover the ventilation openings on the front and rear side of the appliance box (Figure 5). Install the panel-mounted housing in the correct position - horizontally or vertically aligned in the wall.
  • Page 8 Control 9 Client, Control 9 KNX Labelling Function Audio R in Input, audio signal, right Audio L in Input, audio signal, left Audio GND GND audio inputs Audio R out Output, audio signal, right Audio L out Output, audio signal, left Audio GND GND audio outputs Video in...
  • Page 9 Control 9 Client, Control 9 KNX Download configuration data with the commissioning software. - or - Configuration data is saved on a USB stick or SD card. Insert USB stock or SD card into the appropriate slot – (5) or (11). In the KNX user interface, select the entry "Commissioning"...
  • Page 10: Warranty

    The warranty follows about the specialty store in between the legal framework as provided for by law Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. 82576732 03.06.2016 10/11...
  • Page 11 Control 9 Client, Control 9 KNX Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95 - 602-0 Fax +49(0)21 95 - 602-191 www.gira.de info@gira.de 82576732 03.06.2016 11/11...

This manual is also suitable for:

Knx control 9