1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Always disconnect device before working on it. At the same time, take into account all
circuit breakers that supply dangerous voltage to the device.
Do not operate the screen with sharp or pointed objects.
Do not use sharp objects for cleaning. Do not use acids or organic solvents.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
(1) Touch screen surface
3 Function
System information
This device is a product of the KNX system and complies with the KNX directives. Detailed
technical knowledge obtained in KNX training courses is a prerequisite to proper
understanding.
The function of this device depends upon the software. Detailed information on loadable
software and attainable functionality as well as the software itself can be obtained from the
manufacturer´s product database. Planning, installation and commissioning of the device are
carried out with the aid of KNX-certified software. The latest product database and technical
descriptions are always available on the homepage.
Intended purpose
-
Operating consumers and displaying the status of systems and information e.g. light
switching, dimming, controlling curtains, temperature and consumption values, emails or
messages etc.
-
Flush-mounted installation in hollow or solid walls in the interior
Product characteristics
-
Illuminated programmable TFT graphic colour screen, 320x240 pixels, 4096 colours
-
Touch screen, operation via touch directly on the screen
-
Installation position horizontal or vertical
32563342
10499271 I02
Figure 1: Front side
01.07.2011
1/14

Advertisement

loading

Summary of Contents for Gira KNX/EIB

  • Page 1 KNX/EIB InfoTerminal Touch InfoTerminal Touch Order-No. : 2072 .. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
  • Page 2: Operation

    KNX/EIB InfoTerminal Touch USB port for fast programming by means of PC Max. of 1600 operating functions, 400 display functions Max. of 50 pages Max. of 24 light scenes with 32 actuator groups Week time switch with 16 time programs, 8 switching times for each (optional astro or random function) Max.
  • Page 3 KNX/EIB InfoTerminal Touch Status line If programmed, the status line (2) will be visible at the upper screen edge. The status line displays up to ten elements: Event display Centralized fault message Value display Date, time of day, ASCII texts Screen page Control and display elements (4) or images are displayed on screen pages (3).
  • Page 4 KNX/EIB InfoTerminal Touch The switching times for the selected timer function will be displayed. Select the switching time to be changed. The page showing the selected switching time will be displayed. Select Time of day and enter the desired switching time via the keypad. Accept input by pressing Save.
  • Page 5 KNX/EIB InfoTerminal Touch Complete the entry and reject the settings by pressing Cancel. Quit the Light scenes page by pressing Return. i As an alternative, a light scene can be adjusted manually on the KNX operating devices. After that, highlight the desired scene on the Light scenes page and press Call memory for >...
  • Page 6 KNX/EIB InfoTerminal Touch Press Display settings Press Brightness settings Select basic brightness: Bright, Dim or Off. The new setting will be visible as soon as the device switches back into the basic brightness. Setting the date Open the Service page...
  • Page 7 KNX/EIB InfoTerminal Touch Select Default settings A confirmation request appears on the screen asking whether the default setting is to be restored and whether all user data is to be deleted. If the user data is not to be deleted: Press No.
  • Page 8 KNX/EIB InfoTerminal Touch Opening email box. The email function is set up and activated. Open Email page. The available mailboxes are displayed. Press the desired mailbox. The desired mailbox is opened and the available emails are listed. Updating email box The email boxes are updated cyclically or manually depending on programming.
  • Page 9 KNX/EIB InfoTerminal Touch Press the desired news service longer than 5 s. Alarm system i The instructions described below concern the alarm system integrated in the device and the operation solely from the device. If other operating devices are installed in the KNX system, the operational steps must be carried out accordingly.
  • Page 10 KNX/EIB InfoTerminal Touch Resetting fault If a warning device does not respond to an automatic request, the system switches to the status Fault. The display indicates the status Fault. Remove fault. Press Confirm on the device. When all faults have been removed, the system switches to the status deactivated.
  • Page 11 KNX/EIB InfoTerminal Touch The start of the presence simulation can be delayed for up to 24 hours: Press Start delay, enter the desired time period in hours and press Save. i If the presence simulation should start without delay, enter the value 0 as start delay.
  • Page 12 KNX/EIB InfoTerminal Touch Install the panel-mounted housing in the correct position - horizontally or vertically aligned in the wall. Horizontal installation: Arrow OBEN TOP points upwards. Vertical installation: Arrow OBEN TOP points to the left. Pull bus and 230 V lines through the designated bushings.
  • Page 13 KNX/EIB InfoTerminal Touch 5.2 Commissioning Downloading the physical address The device must have been connected and ready for use. Programming key (10) and LED (9) on the bottom side of the device must be accessible. Configuration and startup with ETS2 version 1.3a or ETS3.0d or later.
  • Page 14: Warranty

    The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. Gira Giersiepen GmbH & Co. KG...