PROBLEM
COOLING is poor.
If REFRIGERATOR
TEMPERATURE
is too low.
DEFROSTING is
NO DEFROSTING.
poor.
INDICATED BY
CHECK
1. If FREEZER TEMPERATURE
is n ormal.
2. If amount of cool air from
FAN MOTOR is
sufficient.
3. Door Line contact.
1. If HEATER emits heat.
2. If DRAIN PIPE is
blocked.
3. If ice remains after
DEFROSTING.
CHECKING METHOD
CAUSE
Check is FREEZER
TEMPERATURE is too low.
Make sure that the amount
FAN MOTOR is poor.
and speed of cool air are
Passage of cool air
sufficient by touching the
is blocked.
check supplied on the
EVA frozen.
REFRIGERATOR.
Check door seal when
Door liner damaged.
door is closed.
USE TEST MODE2
HEATER disconnection.
(forced DEFROSTING).
TEMPERATURE FUSE
disconnection.
Connection is poor.
DEFROST-SENSOR is poor.
HEATER RELAY is poor.
Check DRAIN PIPE.
DRAIN PIPE is blocked.
Make sure that DEFROST
Connection is poor.
SENSOR is connected.
Make sure that FREEZER /
DOOR does not close
REFRIGERATOR DOOR is closed.
properly.
SOLUTION
Make sure the
DOOR isattached.
Replace FAN MOTOR.
Remove impurities.
See DEFROSTING is poor .
Replace Door liner.
Replace HEATER.
Replace TEMPERATURE
FUSE.
Check EVAPORATOR
connection and wire of MAIN
PWB CONNECTOR.
Replace DEFROST-SENSOR.
Replace RY3 of MAIN PWB.
Remove ice and impurities.
Check HEATER PLATE
resistance.
Reassemble the
DEFROST-SENSOR.
Reassemble DOOR.
Replace GASKET.