Bante Instruments 810 User Manual

Bante Instruments 810 User Manual

Benchtop dissolved oxygen meter

Advertisement

Quick Links

Bante 810 Benchtop Dissolved Oxygen Meter
USER MANUAL
Bante Instruments Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 810 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bante Instruments 810

  • Page 1 Bante 810 Benchtop Dissolved Oxygen Meter USER MANUAL Bante Instruments Inc.
  • Page 2 Overview Connectors Introduction Thank you for selecting the 810 benchtop dissolved oxygen meter. This user manual provides a step-by-step guide to help you operate the meter, please carefully read the following instructions before use. Any use outside of these instructions may invalidate your warranty and cause permanent damage to the meter.
  • Page 3 Overview Remove the plastic cover from the right side of the electrode Function arm. • Switch the meter on or off • Lock or unlock the measurement • Exit the calibration, settings and return to the measurement mode Toggle between the % saturation and mg/L (ppm) mode Use the screwdriver to tighten the screw moderately.
  • Page 4 Setup Meter Setup The 810 meter contains an integrated setup menu for customizing the displayed option to meet measurement requirements. The following table describes the functions of each menu item. Menu Item Option and Description Salinity Coefficient 2.2 Insert 6-pin connector into the connector socket labeled DO.
  • Page 5 Press the  /  key to select an option, press the Enter key to The 810 meter allows 1 or 2 points dissolved oxygen calibration. If you confirm and switch to the next menu item. have selected the single point calibration in the setup menu, we...
  • Page 6 CAL2/0%, the meter prompts. The 810 meter can be used to measure the water, wastewater, brine you to continue with second point calibration. and other liquids. If your sample is seawater or water containing large amounts of salt, make sure to set the salinity coefficient before measurement.
  • Page 7 ) reagent and a small amount of cobalt (II) chloride hexahydrate (CoCl O) in the 250 ml • distilled water, mix the solution until reagent is completely dissolved. Meter Specifications Model Bante 810 Dissolved Oxygen Range 0.0 to 20.0 mg/L Resolution 0.1 mg/L Accuracy ±...
  • Page 8 Tel: (+1) 346-762-7358 E-mail: banteinstruments@yahoo.com Factory: F3, Building 2, No.2185, Laifang Rd., Shanghai 201615, China Tel: (+86) 21-6404-1598 E-mail: banteinstrument@hotmail.com The information in this document is subject to change without notice.  www.bante-china.com Copyright © Bante Instruments Inc, 2022. All rights reserved.