  • Page 1 ThermoScan ® Ear thermometer 귀적외선체온계 IRT6510...
  • Page 3 Helen of Troy Limited and/or its affiliates. ® Distributed for: Kaz USA, Inc., a Helen of Troy Company 400 Donald Lynch Blvd., Marlborough, MA 01752 © 2020 All rights reserved. Patents: www.kaz.com/patents/braun Designed in Germany. Made in Mexico. P/N: A000840R4 29JUN20...
  • Page 4 IRT6510...
  • Page 5: Product Description

    This thermometer must only be used with genuine Braun ThermoScan lens filters (LF 40). ® To avoid inaccurate measurements always use this thermometer with a new, clean Braun lens filter attached. If the thermometer is accidentally used without a Braun lens filter attached, clean the lens (see «Care and cleaning»...
  • Page 6: Body Temperature

    ® eardrum and surrounding tissues. To help avoid inaccurate temperature measurements, the probe tip (pre warm tip) is warmed to a temperature close to that of the human body. When the Braun ThermoScan is placed in the ear, it ®...
  • Page 7 Oral temperatures are influenced by drinking, eating and mouth breathing. Rectal temperatures often lag behind changes in core body temperature and there is a risk of cross-contamination. How to use your Braun ThermoScan ® Remove the thermometer from the protective case.
  • Page 8 The Braun lens filter indicator will blink to signal one is needed. To achieve accurate measurements, make sure a new, clean Braun lens filter is in place before each measurement. Attach a new Braun lens filter by pushing the thermometer probe straight into the Braun lens filter inside the box and then pulling out.
  • Page 9: Temperature Taking Hints

    Temperature taking hints Always replace disposable Braun lens filters to maintain accuracy and hygiene. The right ear measurement may differ from the measurement taken in the left ear. Therefore, always take the temperature in the same ear. The ear must be free from obstructions or excess earwax build-up to take an accurate reading.
  • Page 10: Memory Mode

    Memory mode This model stores the last 9 temperature measurements. To display the stored measurement, the thermometer must be turned on. Press the Mem button. The display shows the temperature, and when releasing the Mem button, the stored temperature for that memory number is displayed, together with “M”.
  • Page 11: Care And Cleaning

    Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners. Never submerge this thermometer in water or any other liquid. Store thermometer and Braun lens filters in a dry location free from dust and contamination and away from direct sunlight.
  • Page 12: Errors And Troubleshooting

    Make sure the probe tip (pre warm tip) and lens are clean and a new, clean typical human temperature range Braun lens filter is attached. Make sure (34 – 42.2 °C). the thermometer is properly inserted. HI = too high Then, take a new temperature.
  • Page 13: Product Specifications

    Product specifications Displayed temperature range: 34 – 42.2 °C Operating ambient temperature range: 10 – 40 °C Storage temperature range: -25 – 55 °C Operating and storage relative humidity: 10 – 95 %RH (non condensing) Display resolution: 0.1 °C Accuracy for displayed temperature range Maximum Laboratory Error •...
  • Page 14: Limited Warranty

    The warranty becomes void if repairs are undertaken by unauthorized persons and if original Braun parts are not used. Guidance and manufacturer’s declaration – electromagnetic emissions The IR thermometer equipment is intended for use in the electromagnetic environment specified below.
  • Page 15 Field strengths outside the shielded location from fixed RF Radiated RF 3 V/m 80MHz to Complies transmitters, as determined by 2.5GHz IEC 61000-4-3 an electromagnetic site survey, should be less than 3 V/m. Interference may occur in the vicinity of equipment marked with the following symbol: Not applicable Conducted RF...
  • Page 16 IRT6510...
  • Page 17 제품 개요 IRT6510 브라운 렌즈필터 (총 20개들이 1박스) 온도감지부 끝부분(예열팁) 온도감지부(프로브) ExacTemp 표시등 브라운 렌즈필터 분리 스위치 액정화면 메모리 버튼 전원 버튼 시작 버튼 건전지 삽입구 보관함 브라운 써모스캔 귀적외선체온계는 정밀하고 안전하며 빠르게 귀에서 체온을 측정 할 수 있도록 개발되었습니다. 체온계...
  • Page 18 브라운 렌즈필터를 끼우지 않은 상태에서 실수로 본 제품을 사용한 경우, 렌즈를 청소하십시 오 («청소 및 보관» 항목을 참조하십시오). 브라운 렌즈필터는 어린이의 손이 닿지 않는 곳 에 보관하십시오. 본 제품은 일반 가정용 의료기기입니다. 본 제품은 질병을 진단하기 위한 목적이 아니며, 신 체의...
  • Page 19 체온의 범위 정상 체온은 일정 범위가 있습니다. 정상 체온은 측정 부위에 따라 달라지며, 연령 에 따라 점차 감소합니다. 정상 체온의 범위는 각 개인별로도 차이가 있고, 하루 중 에도 변화됩니다. 따라서 정상 체온 범위는 평소 측정을 통하여 정확히 숙지하는 것이 중요합니다. 이러한 측정은 브라운 써모스캔을 이용하시면 간편히 하실 수 있 습니다.
  • Page 20 브라운 써모스캔 사용방법 보관함에서 체온계를 분리합니다. 전원 버튼 을 누릅니다. 내부 자가검사 과정 중에는 액정화 면에 모든 그림이 표시됩니다. 그 런 다음, 5초 동안 마지막에 측정 된 체온이 표시됩니다. 브라운 렌즈필터를 끼우지 않은 경 우, 브라운 렌즈필터 표시등이 깜빡거 립니다. 항상...
  • Page 21 체온 측정이 진행중인 동안에는 ExacTemp 표시등이 규칙적으로 점멸합니다. 이 표시등이 3초 동안 중단 없이 표시되면 체온 측정 이 성공적으로 완료되었음을 나타냅니다. 주의사항: 외이도에 온도감지부(프로브)가 잘 맞춰진 상태로 측 정이 되었다면, 측정이 완료되었음을 알려주는 삐 소리가 길게 납 니다. 온도감지부(프로브)가 체온을 측정하는 동안 안정되지 않고 외이 도...
  • Page 22 아래의 경우에는 20분 정도 기다리신 후 체온을 측정하십시오. 요인 영향을 미칩니다 방의 온도가 지나치게 높거나 낮은 경우 보청기 착용 베개에 누운 상태 한쪽 귀를 치료 중이거나 약을 바르신 경우에는, 다른 편 귀에 사용하십시오. 메모리 모드 본 제품은 마지막 9개의 체온 측정값을 저장합니다. 저장된 측정값을...
  • Page 23 청소 및 보관 온도감지부 끝부분(예열팁)은 가장 민감한 부분입니다. 이 부분 은 정확한 측정을 위해서 항상 깨끗하고 손상되지 않도록 유지하 여 주십시오. 브라운 렌즈필터 없이 체온을 측정하였다면 아래와 같이 조치하시기 바랍니다. 면봉이나 알코올을 묻힌 부드러운 천으로 조심스럽게 렌즈를 닦 으십시오. 알코올이 완전히 증발하면 새로운 브라운 렌즈필터를 끼운...
  • Page 24 이상 발생시 조치 방법 에러 메시지 상태 해결 방법 브라운 렌즈필터가 부착되어 있지 깨끗한 새로운 브라운 렌즈필터를 끼우십시오. 않은 경우 체온계 온도감지부(프로브)가 귀에서 온도감지부(프로브)의 위치가 정확한 위치에 있지 않고 정확한 체온 정확하고 움직임이 없도록 측정이 불가능한 경우 유지하십시오. 브라운 렌즈필터를 교체하고 다시 POS = 위치...
  • Page 25 제품 사양 체온측정범위: 34 – 42.2 °C 제품 사용가능 외부온도: 10 – 40 °C -25 – 55 °C 보관온도범위: 10 – 95 %RH 작동과 보관 관련 습도: 0.1 °C 측정단위: 측정오차 실험실 정확도 • 35 °C - 42 °C: ± 0.2°C •...
  • Page 26 지침 및 제조업체 선언 - 전자파 방사 적외선 체온계는 아래에서 지정되는 전자파 환경에서 사용하기 위한 것입니다. 적외선 체 온계의 고객과 사용자는 적외선 체온계가 그런 환경에서 사용될 것을 보장해야 합니다. 방사 시험 적합 여부 전자파 환경 - 지침 ME 기기는 그 내부 기능 수행을 위해서만 RF 에너지 방사...
  • Page 27 전원 주파수 자기장은 전형적인 전원 주파수 자기장 상용 전원 또는 병원 환경에서 적합 3 A/m 의 전형적인 장소의 특성 수준 IEC 61000-4-8 으로 되어 있어야 합니다. >95% 강하 주기 전원 입력선에서의 전 압 강하, 순시정전 및 ME 기기는 건전지로만 전원을 강하...
  • Page 28 본 제품은 철저한 품질관리와 검사를 거쳐 제조되어 수입된 제품입니다. 아래 기재된 내용으로 품질을 보증합니다. 제품 모델명 구입일 시리얼번호/로트번호 이 름 판매점 명 (인) 판 고 매 주 소 주 소 객 점 연락처 연락처 수입업자: ㈜사이넥스 / 서울시 강남구 논현로 430, 10층 품질보증...