Cleaning And Maintenances; Troubeshooting - Light Sky F400LL User Manual

Table of Contents

Advertisement

●In order to ensure the projector could work normally.It should be kept clean always .It is recommended that the
fans and ventilation in let should be cleaned every 15 days.The lens and dichroic colour filters should also be reg
-ularly cleaned to maintain an optimum light output.Do not use any type of solvent on dichroic colour filters.It will
damage the projector.
●Suggestion:The continue usage of the light don't exceed 4 hours.Or it will shorter the usage of the lamp.Please
use the alternative operation to solve this problems.
●Please disconnect the power supply when begin to maintenaceor takedown the light.Please let the parts cool
down 10 minute at least then begin to install.If need to replace the lamp,please wait 10 minute again at least to
let the lamp cool down completely or which maybe burned down.
●Please inspect the lens or other moving parts timing and keep them clear and static.If find anything damaged or
losseness,must change a lamp or fix the lamp in order to avoid the accident.
●The light use the strong cool system. It is easy for the dirty to be collected .Please do clear the hot-sak one time
two week at least.
●After you use the light,please check the intake place whether there are some wastepaper,please clean it up,or
the windmill will break down and causing fire.
It is recommended some solution for some normal trouble shooting.Any unsolutioned problems should always
be handle by the professional person.Disconnect the power supply before maintenance the light.
■Lamp off:
◎Please check if install the suitable lamp.
◎Please check the connection of the power supply or switch is ok.
◎Please check whether the lamp will reach the end of their life can explode ,please replace a same description
lamp.
◎Please measure if the power supply is enough.
◎Please check if the operation is correct.Please wait 30 minutes at least till the lamp cool down enough,then
could the connect the power supply,which could be normal work.
◎Please check whether the DMX 512 controller pass the "turn on" order.
◎Please check the connection of the trigger circuit is loose contact.
◎Please check whether the connected point of the trigger point is loose contact ,faster the connect cable .
◎Check menu "information" →fan speed/voltag→fan1, fan2,fan3",Whether the fan speed in 500RPM
above,below 500RPM the lamp does not light,replace with the specifications of the fan.
◎ Please check if the switch of the temperature is damaged.
Enter the menu "information"select "temperature"to see whether the temperature display boad is too
high or no temperature display.
■The light beam is dark,not inhomogeneou:
◎When the lamp is to the usage life,the light is not enough,please change a new one for the same description .
◎Please check the reflector parts is dirty.Keep them clear.
◎Please measure if the power supply is enough.
◎Small adjusting is suitable for change height or screw system till get a ideal light beam.
Enter the menu"service options"to choose "calibration"to enter the "Color" and"Gobo"
adjustment,the center can be modulated.

CLEANING AND MAINTENANCES

TROUBESHOOTING

23

Advertisement

Table of Contents
loading

Table of Contents