MECHANICAL INSTALLATION

Section 2
2.1

Dimensions and Weights

Model
CSX-007
CSX-015
CSX-018
CSX-022
CSX-030
CSX-037
CSX-045
CSX-055
CSX-075
CSX-090
CSX-110
2.2

Physical Installation

CSX-007 ~ CSX-055: Allow 100 mm (3.94 inches) between soft starters.
CSX-075 ~ CSX-110: Allow 200 mm (7.88 inches) between soft starters.
CSX-007 ~ CSX-055: Allow 50 mm (1.97 inches) between the soft starter and solid surfaces.
CSX-075 ~ CSX-110: Allow 200 mm (7.88 inches) between the soft starter and solid surfaces.
Soft starters may be mounted side by side with no clearance.
The soft starter may be mounted on its side. Derate the soft starter's rated current by 15%.
.
Page 2
Mechanical Installation
A
B
C
mm
mm
mm
(inch)
(inch)
(inch)
98
82
203
(3.86)
(3.23)
(7.99)
145
124
215
(5.71)
(4.88)
(8.46)
202
160
240
(7.95)
(6.30)
(9.45)
D
E
F
mm
mm
mm
(inch)
(inch)
(inch)
188
165
55
(7.40)
(6.50)
(2.17)
196
193
-
(7.71)
(7.60)
204
214
-
(8.03)
(8.43)
CSX
G
H
Weight
mm
mm
kg (lb)
(inch)
(inch)
90.5
23
2.2
(3.56)
(0.9)
(4.85)
110.5
37
4.0
(4.35)
(1.46)
(8.82)
114.5
51
6.1
(4.50)
(2.0)
(13.45)
710-02407-00G