1.
Caution Statements ......................................................................................................... 2
2.
Mechanical Installation .................................................................................................... 3
3.
Electrical Installation ........................................................................................................ 4
4.
Adjustments ......................................................................................................................... 7
5.
Troubleshooting ................................................................................................................ 8
6.
Accessories .......................................................................................................................... 9
7.
Specifications .................................................................................................................... 10
The examples and diagrams in this manual are included solely for illustrative purposes. The
information contained in this manual is subject to change at any time and without prior notice.
In no event will responsibility or liability be accepted for direct, indirect or consequential
damages resulting from the use or application of this equipment.
Ce manuel est également disponible en français à partir de www.aucom.com.
Dieses Handbuch ist auch in deutscher Sprache aus www.aucom.com.
Questo manuale è disponibile anche in italiano da www.aucom.com.
Este manual também está disponível em Português no site www.aucom.com.
Este manual también está disponible en español a partir de www.aucom.com.
www.aucom.com.
© 2015 AuCom Electronics Ltd. All Rights Reserved.
CSX

Advertisement

loading
Need help?

Need help?

Do you have a question about the CSX-007 and is the answer not in the manual?

Questions and answers

Summary of Contents for AuCom CSX-007

  • Page 1: Table Of Contents

    In no event will responsibility or liability be accepted for direct, indirect or consequential damages resulting from the use or application of this equipment. Ce manuel est également disponible en français à partir de www.aucom.com. Dieses Handbuch ist auch in deutscher Sprache aus www.aucom.com.
  • Page 2: Caution Statements

    CAUTION STATEMENTS Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and understand all instructions in this manual prior to installing, operating or maintaining the equipment, to follow good electrical practice including applying appropriate personal protective equipment and to seek advice before operating this equipment in a manner other than as described in this manual.
  • Page 3: Mechanical Installation

    CSX-075 ~ CSX-110: Allow 200 mm (7.9 inch) between soft starters. CSX-007 ~ CSX-055: Allow 50 mm (2.0 inch) between the soft starter and solid surfaces. CSX-075 ~ CSX-110: Allow 200 mm (7.9 inch) between the soft starter and solid surfaces.
  • Page 4: Electrical Installation

    ELECTRICAL INSTALLATION Electrical Installation 3.1 Power Terminations L1/1, L2/3, L3/5, T1/2, T2/4, T3/6 A1, A2, A3, 01, 02, 13, 14, 23, 24 mm (AWG) (AWG) 007 - 030 037 - 055 075 - 110 007 - 110 (0.43) 10 - 35 25 - 50 N.A.
  • Page 5 ELECTRICAL INSTALLATION 3.3 Control Circuits WARNING Isolate the CSX completely from the power supply before attempting any work on the CSX or motor. Control terminals may be at phase voltage potential. AVERTISSEMENT Isoler complètement le CSX de l'alimentation secteur avant de tenter toute intervention sur le CSX ou sur le moteur.
  • Page 6 ELECTRICAL INSTALLATION 3.5 Electrical Schematics Soft starter installed with a motor protection Soft starter installed with a motor protection circuit breaker circuit breaker and main contactor 1/L1 2/T1 1/L1 2/T1 3/L2 4/T2 3/L2 4/T2 5/L3 6/T3 5/L3 6/T3 Motor (three phase) Main contactor 13, 14 Main contactor output 23, 24 Run contactor output...
  • Page 7: Adjustments

    ADJUSTMENTS Adjustments Initial Start Voltage Start Ramp Time Stop Ramp Time 03243.D Initial Start Voltage Select the initial start voltage (A). Application Initial Start Voltage - Suggested setting Centrifugal Pump Submersible Pump Screw Compressor Conveyor Crusher Other applications Start Ramp Time Select the start ramp time (B).
  • Page 8: Troubleshooting

    TROUBLESHOOTING Troubleshooting 5.1 LEDs LED Status Ready No control power Motor not running Ready Motor running at full speed Flash Starter tripped Motor starting or stopping 5.2 Trip Codes The Ready LED will flash a different number of times to indicate the cause of the trip. Ready LED Description Power Circuit: Check mains supply (L1, L2, L3), motor circuit (T1, T2, T3), soft starter SCRs and bypass relays.
  • Page 9: Accessories

    Ethernet (Profinet, Modbus TCP, Ethernet/IP), Profibus, DeviceNet, Modbus RTU, and USB. 6.4 PC Software WinMaster can be used with AuCom soft starters to provide the following functionality for networks of up to 99 soft starters: Operational control (Start, Stop, Reset, Quick Stop)
  • Page 10: Specifications

    = With motor protection 7.2 Current Ratings AC53b 4-6:354 AC53b 4-20:340 < 1000 metres < 1000 metres 40 °C 50 °C 40 °C 50 °C CSX-007 18 A 17 A 17 A 15 A CSX-015 34 A 32 A 30 A 28 A...
  • Page 11 SPECIFICATIONS Ferraz/Mersen Fuse Bussmann Fuse Bussmann Fuse SCR I Model European/IEC Style Square Body British Style (170M) (BS88) (North American Style) 6.6URD30xxxA0063 CSX-007 1150 170M-1314 63 FE (A070URD30xxx0063) 6.6URD30xxxA0125 CSX-015 8000 170M-1317 160 FEE (A070URD30xxx0125) 6.6URD30xxxA0160 CSX-018 10500 170M-1318 160 FEE (A070URD30xxx0160) 6.6URD30xxxA0160...
  • Page 12 Voltage dip and short time interruption ........... 100 ms (at 40% nominal voltage) Harmonics and distortion ............IEC61000-2-4 (Class 3), EN/IEC61800-3 Short Circuit Rated short-circuit current CSX-007 to CSX-022 ................. 5 kA Rated short-circuit current CSX-030 to CSX-110 ................10 kA Semiconductor Fuses These short circuit ratings are with fuses used as given in the table under page 10.