Advertisement

Quick Links

EQ RC30 Manual Reservoir
IDH 2814022
Operating Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Loctite EQ RC30

  • Page 1 EQ RC30 Manual Reservoir IDH 2814022 Operating Manual...
  • Page 2: Table Of Contents

    Table of Contents Please Observe the Following ....................3 Emphasized Sections ......................3 For Your Safety ........................3 Unpacking and Inspection ....................3 Packing List ........................... 4 Features ..........................4 Field of Application (Intended use) ................... 4 Description ........................... 5 2.1 Theory of Operation ........................
  • Page 3: Please Observe The Following

    Observe general safety regulations for the handling of chemicals such as ® Loctite adhesives and sealants. Observe the manufacturer’s instructions as stated in the Safety Data Sheet. While under warranty, the unit may be repaired only by an authorized Loctite service representative. Unpacking and Inspection ® Carefully unpack the Loctite EQ RC30 Manual Reservoir and examine the items contained in the carton.
  • Page 4: Packing List

    Accommodates a variety of Loctite packages. Field of Application (Intended use) The Loctite EQ RC30 Manual Reservoir is suitable for the application of Loctite adhesive with a manual applicator at manual workstations such as in workshops, laboratories, and industrial installations.
  • Page 5: Description

    The Loctite EQ RC30 Manual Reservoir is connected to an external pneumatic supply. An uncovered bottle of Loctite® product is placed directly into the EQ RC30 Manual Reservoir, the feedline is inserted into the product, and the reservoir lid is clamped in place.
  • Page 6: Technical Data

    1. Reservoir Pressure Regulator 6. Reservoir Knob x 3 2. Air Pressure ON/OFF Switch 7. Reservoir Lid 3. Reservoir Pressure Gauge 8. Pneumatic Connection P in 4. Valve Pressure Relief 9. Low Level Connector XS2 5. Reservoir/Feedline Fitting 10. Low Level Sensor Technical Data Dimensions (L x H x W): 214x363x357 mm...
  • Page 7: Installation

    Installation Before using the equipment for the first time check it carefully for signs of external damage. If any shipping damage is found DO NOT USE THE EQUIPMENT – return it to your supplier immediately. 4.1 Environmental and Operating Conditions Keep product feedline as short as possible.
  • Page 8: Connecting The Unit

    Use flexible pneumatic hoses and Loctite supplied product feedlines to prevent unnecessary loads on the fitting and to ensure compatibility. Keep all fittings tight. No direct sunlight; no UV light. No condensing humidity. Avoid direct contact with water. 4.2 Connecting the Unit Use only the cable and hose sets supplied.
  • Page 9: Filling And Refilling The Product Reservoir

    The pneumatic and safety devices would become clogged and therefore ineffective! Warning! Before loosening the reservoir locking knobs (6), the EQ RC30 Manual Reservoir must be depressurized (pressure-free)! When dispensing cyanoacrylate and an empty signal is shown, refill the product reservoir immediately, since air in the product line results in curing of the product! The reservoir is depressurized when the depressurizing valve (2) is in “OFF”...
  • Page 10: Operation

    • Continue dispensing with the selected dispensing pressure. Operation 5.1 First Operation: Warning! Before loosening the reservoir locking knobs (6), the EQ RC30 Manual Reservoir must be depressurized (pressure-free)! The EQ RC30 Manual Reservoir is depressurized when the reservoir pressure gauge indicates no pressure.
  • Page 11: Adjust The Level Sensor

    Notice: To avoid air bubbles during dispensing, the product line must be filled and then purged of air. • Position the dispensing valve as specified in its instruction manual to ensure bubble-free filling of the product line. • Set the pressure regulator (2) to a dispensing pressure of 0.5bar (approx. 7 psi) and open the manual dispense valve until the produce flows out.
  • Page 12 the base of the reservoir to raise the height of the bottle to reduce the residual adhesive in the bottle when low level is used. Before adjusting the Level Sensor: 1. Remove the plastic cap from the backside of reservoir. 2.
  • Page 13: Application Hints

    • Reconnect the pneumatic supply to the unit. • Check the installation according to Chapter 4. • Return to operation according to Section 5.1. Troubleshooting Before proceeding with any repair or maintenance operation disconnect the EQ RC30 Manual Reservoir from the main air supply.
  • Page 14 Malfunction Possible Cause Corrective No air pressure present. Check pneumatic supply. No needle movement on Product reservoir not Check product reservoir. the pressure gauge. switched on. Pressure gauge is defect. Replace pressure gauge. The desired pressure is not Supply pressure Increase the supply pressure.
  • Page 15: Care And Maintenance

    -Clean, dry, filtered air must be used. If it is not, the solenoids on the controller will be fouled over time. Notice: If the required air quality is not achieved, install a Loctite® filter regulator. In the US order a 5 m filter using Part Number 478603. In Europe or Asia,...
  • Page 16: Accessories And Spare Parts

    Anti-Bubbler Kit, 2 Adapters & 2 Sleeves 478569 Silicone Grease, 6 Gram Tube 88722 Accessories Loctite Air Filter, Regulator, Gauge (Mechanical version) - US 478603 Loctite Air Filter, Regulator, Gauge (Mechanical version) – EU/Asia 88649 Diagrams EQ RC30 Manual Reservoir Pin Connection:...
  • Page 17: Warranty

    Warranty ® Henkel expressly warrants that all products referred to in this Instruction Manual for Loctite EQ RC30 Manual Reservoir (hereafter called “Products”) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, as its option, to replacing...
  • Page 18: Declaration Of Conformity

    THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS. WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH, THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS AND SPECIAL, INDIRECT OR CONSEQUENTIAL...
  • Page 19 #03-01/02 Haw Par Technocentre Zhangjiang, Hi-Tech Park, Pudong, Loc. Tulpetlac, C.P. 55090 SINGAPORE 149598 Shanghai, China 201203 Ecatepac de Morelos, MEXICO Henkel Loctite Korea Henkel Japan Ltd. Henkel AG & Co. KGaA 8F, Mapo Tower, 418, 27-7 Shin Isogo-cho, Isogo-ku Henkelstraße 67,...

Table of Contents