Oakton 35630-00 Operating Instructions Manual

Oakton 35630-00 Operating Instructions Manual

Portable ph/con 10 and waterproof ph/con 10 meter

Advertisement

Quick Links

12. Warranty
OAKTON warrants this meter to be free from significant deviations in material
and workmanship for a period of one year from date of purchase. OAKTON
warrants this probe to be free from significant deviations in material and
workmanship for a period of six months from date of purchase. If repair or
adjustment is necessary and has not been the result of abuse or misuse within
the warrantied time period, please return—freight prepaid—and correction will
be made without charge. OAKTON alone will determine if the product problem
is due to deviations or customer misuse.
Out-of-warranty products will be repaired on a charge basis.
13. Return of items
Authorization must be obtained from our Customer Service Department before
returning items for any reason. When applying for authorization, please include
data regarding the reason the items are to be returned. For your protection, items
must be carefully packed to prevent damage in shipment and insured against possi-
ble damage or loss. We will not be responsible for damage resulting from careless or
insufficient packing. A restocking charge will be made on all unauthorized returns.
NOTE: We reserve the right to make improvements in design, construction, and
appearance of products without notice.
68X230403 00702-09 rev 06/00
OPERATING INSTRUCTIONS
Portable pH/CON 10
and Waterproof
pH/CON 10 Meter
MEAS
pH
C
ATC
pH/Conductivity/ C Meter
pH/Con 10 Series
ON
OFF
MODE
HOLD
CAL
ENTER
MEAS
OAKTON
®
35630-00, 35630-02
WATERPROOF
MEAS
READY
µS
C
ATC
pH/Conductivity/°C Meter
pH/CON 10 Series
Printed in Singapore. 06/00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 35630-00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oakton 35630-00

  • Page 1 35630-00, 35630-02 OAKTON warrants this meter to be free from significant deviations in material and workmanship for a period of one year from date of purchase. OAKTON warrants this probe to be free from significant deviations in material and workmanship for a period of six months from date of purchase. If repair or...
  • Page 2: Table Of Contents

    Table of Contents 1. Introduction Thank you for selecting an OAKTON meter. The OAKTON pH/CON 10 series 1. Introduction ......................3 meters are microprocessor-based instruments that measures pH, conductivity, and temperature with just one probe. This meters have many user-friendly features—all 2.
  • Page 3: Display And Keypad Functions

    Keypad 2. Display and Keypad Functions The large membrane keypad makes the instrument easy to use. Each button, when pressed, has a corresponding graphic indicator on the LCD. Display ON/OFF....Powers and shuts off the meter. The LCD has a primary and secondary display. HOLD ....Freezes the measured reading.
  • Page 4: Preparation

    Connecting the probe 3. Preparation The OAKTON pH/Con meter uses a specialty combination pH/conductivity/ temperature probe. The probe cable has a notched 6-pin connector to attach the Inserting the Batteries probe to the meter. NOTE: Do not substitute other probes or electrodes. For a replacement probe, Four AAA batteries are included with your meter.
  • Page 5: Calibration

    Connecting the AC Adapter (35630-00 only) 4. Calibration The AC adapter is not included with your meter; order separately on page 22. Important Information on Meter Calibration Insert the AC jack as shown in figure below. Switch off the meter before plugging the adapter into the power source.
  • Page 6: Ph Calibration

    See figure which makes pH calibration faster and easier. See pages 22-23 for information on READY READY our high-quality OAKTON pH buffers. The secondary display automatically scrolls to the next buffer calibration option. • If you are performing multipoint Calibrating for pH: calibration, go to step 7.
  • Page 7: Conductivity Calibration

    Pour out two separate portions of your calibration standard and one of 22-23 for our selection of high-quality deionized water into separate clean containers. OAKTON conductivity calibration If necessary, press the MODE key to select Conductivity Mode. The µS or solutions.
  • Page 8: Temperature Calibration

    Compare the primary display reading Temperature Calibration to a NIST-traceable thermometer or another thermometer known to be The built-in temperature sensor included accurate. in the probe is factory calibrated. Calibrate your sensor only if you suspect tempera- Press the keys to adjust ture errors that may have occurred over a the primary display reading to agree long period of time or if you have a...
  • Page 9: Measurement

    To release the held value, press HOLD If the pH electrode has dehydrated, again. Continue to take measurements. soak it for 30 minutes in OAKTON NOTE: This meter will hold a reading electrode storage solution or a 2M–4M for up to 30 minutes, because it KCl solution.
  • Page 10: Probe Care And Maintenance

    8. Troubleshooting 7. Probe Care and Maintenance Problem Cause Solution Under typical operating conditions, the probe will need to be replaced every 6 to 12 months. In extreme applications, the probe may wear out sooner. Proper Power on but a) Batteries not in place. a) Check that batteries are in care and maintenance will help you receive the maximum probe life and ensure no display...
  • Page 11: Error Messages

    Dimensions: See figure below. 35630-00 Meter: 7.5"L x 3.5"W x 1.75"H (19.1 cm x 8.9 cm x 4.5 cm) If error persists, or the meter shows incorrect values, return the meter.
  • Page 12: Accessories

    Top and side openings let probe and probe connections remain accessible To order OAKTON accessories, contact your OAKTON distributor. WD-35615-07 AC adapter, 9 VDC to 110 VAC. WD-35615-08 AC adapter, 9 VDC to 220 VAC.

This manual is also suitable for:

35630-02