Rear Panel Description - Mackie SA1532Z User Manual

3-way active loudspeaker system
Hide thumbs Also See for SA1532Z:
Table of Contents

Advertisement

reAr pANeL DeScriptiON

1. MAIN INPUT
This is a female XLR-type connector that
accepts a balanced line-level signal from a
mixing console or other signal source.
2. LOOP OUT
This is a male XLR-type connector that
produces exactly the same signal that is
connected to the MAIN INPUT jack. Use it to
daisy-chain several SA1532z's together off the
same signal source.
3. Level Control
This controls the overall signal level at the input to
the built-in power amplifiers. It ranges from –15 dB to
+5 dB of gain. The center detent is 0 dB (unity gain).
4. Power ON Indicator
When the POWER switch is turned on, and the
linecord is connected to an active AC power supply, this
indicator lights green to let you know that you're ready
to rock and roll. The cool blue LED on the front of the
cabinet works in the same way.
5. SIGNAL Present Indicator
This LED illuminates whenever there is a signal pres-
ent at the MAIN INPUT connector on the rear panel.
It senses the signal just after the level control, so if
the level control is turned down, the SIGNAL Present
indicator turns off.
6. LIMIT Indicator
The SA1532z has a built-in limiter that prevents the
amplifier outputs from clipping or overdriving
the transducers. The LIMIT indicator lights
when the limiter is activated. It's okay for the
LIMIT indicator to blink occasionally, but if it
blinks frequently or lights continuously, turn
down the level control until the LIMIT indica-
tor only blinks occasionally.
4
MAIN INPUT
SA1532
ACTIVE SOUND REINFORCEMENT
SPEAKER SYSTEM
LOOP OUT
DESIGNED BY MACKOIDS IN WOODINVILLE, WA, USA
COPYRIGHT ©2004 • THE FOLLOWING ARE TRADEMARKS OR
REGISTERED TRADEMARKS OF LOUD TECHNOLOGIES INC.:
"MACKIE", AND THE "RUNNING MAN" FIGURE • PATENT PENDING
7. THERMAL Indicator
There is also a thermal protection circuit that mon-
itors the internal temperature of the amplifiers and
heatsink. If the temperature should exceed a safe oper-
ating level, this indicator lights and the signal is muted to
allow the amplifiers to cool. When the temperature cools
to a safe level once again, the thermal protection circuit
deactivates and normal operation continues.
Note: Activation of the thermal protection circuit is
an indication that you should take steps to avoid con-
tinued thermal problems. See "Thermal Considerations"
on page 6.
8. POWER Switch
Use this switch to turn the SA1532z on and off. Make
sure the level control is turned down before you turn it
on.
9. AC Receptacle
This is where you connect the AC linecord to provide
AC power to the SA1532z's built-in power amplifiers.
Plug the linecord into an AC socket properly configured
for your particular model.
WARNING:
CAUTION
THIS SURFACE MAY REACH HIGH TEMPERATURE DURING
STANDARD USE. TO ENSURE PROPER OPERATION ALLOW A MINIMUM OF 6 INS.
OF CLEARANCE FROM THIS SURFACE AND ADEQUATE VENTILATION. TO REDUCE
THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED
RISK OF ELECTRIC SHOCK
COMPONENT. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO
DO NOT OPEN
QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
AVIS:
RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR
REPLACE WITH THE SAME TYPE FUSE AND RATING.
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
SERIAL NUMBER
MANUFACTURING DATE
POWER
0dB
Z
SIGNAL
LIMIT
-15 +5
THERMAL
ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents