Electro-pneumatic Control Panel Display Screens
Feedback Control
Control Screen
Feedback
Feedback
Control
To reduce the risk of injury due to electric shock, remove power to the control panel before
entering the control panel to make connections for measurement devices.
Selecting scale feedback
Icon/Field
Icon/Field
Icon/Field
Feedback Type
Feedback
Feedback
Type
Type
K K K - - - Factor*
Factor*
Factor*
20 mA
20
20
mA Mass**
mA
Mass**
Mass**
56
Screen
Screen
Description
Description
Description
Select feedback type:
• None: No feedback enabled.
• Pulse Meter (Volume): A pulse meter measuring volume dispensed must be
connected to CM8281–12 (20 kHz max) to use this feedback type.
• Pulse Meter (Mass): A pulse meter measuring mass dispensed must be
connected to CM8281–12 (20 kHz max) to use this feedback type.
• Scale (Positive): A scale measuring weight is connected; weight is increasing as
material is dispensed.
• Scale (Negative): A scale measuring weight is connected; weight is decreasing
as material is dispensed. This input is used if the STU system is mounted on
a scale.
This field appears if a pulse meter type input is selected. Set the unit value a
single pulse represents.
This field appears if a scale type input is selected. Set the weight associated with
the 20 mA signal input in this field.
Selecting pulse feedback