Start up Guide
P2-Series
Balances

Advertisement

Table of Contents
loading

Summary of Contents for VWR P2 Series

  • Page 1 Start up Guide P2-Series Balances...
  • Page 2 1. CONTENT Models: VWR-203P2 Balance Draft shield Weighing pan Power adapter ×1 ×1 ×1 ×1 Models: VWR-602P2 | VWR-2002P2 | VWR-3101P2 Balance Draft shield Weighing pan Power adapter ×1 ×1 ×1 ×1 *The plug type may vary by country. 2. UNPACKING Keep the packaging should a warranty claim or service be required.
  • Page 3: Recommendations And Warnings

    3. RECOMMENDATIONS AND WARNINGS Operate the device in a room where the temperature ranges between 10–40 °C +40 °C +104°F (50–104 °F) and where the relative humidity is below 80%. Place the balance on a solid surface to ensure stability. To obtain stable and +10 °C repeatable weighing results, an anti-vibration table is recommended.
  • Page 4: Components Assembly

    5. COMPONENTS ASSEMBLY Models: VWR-203P2 Models: VWR-602P2 | VWR-2002P2 | VWR-3101P2 6. PREPARING FOR WORK 6.1. Temperature stabilization time Prior to switching the device on, let it Connect the power adapter Connect the power reach room temperature (estimated to DC connector.
  • Page 5: Home Screen

    6.3. Switch the balance on Your balance is ready to use! To switch the device on, press ON / OFF key. 7. PANEL AND SCREEN 7.1. Panel keys Switching Navigation ON/OFF and taring Selecting working Navigation mode / ESC and zeroing Sending weighing result to a printer or a computer / ENTER...
  • Page 6: Basic Operations

    Mass right accuracy and weight value, which value depends on balance type model standard [g] and capacity. VWR-203P2 VWR-602P2 Prior to adjustment prepare the right mass standard. You VWR-2002P2 2 000 are recommended to use a mass standard of class F1 or F2.
  • Page 7 Unload the weighing pan. Adjustment completed. 8.2. Zeroing With unloaded weighing pan press With unloaded weighing pan press key. key. The balance has been zeroed. 8.3. Taring With loaded weighing pan, upon result The balance has been tared. stabilization, press key.
  • Page 8: Working Modes Accessibility

    8.4. Working modes accessibility Simultaneously press keys to enter Using key select “P3.Func” parameter home screen. and press key. While “3.1.UUGG” parameter is on, press key. Using Using key select “3.1.1.Acc” parameter key select “3.1.1.Acc” parameter and press and press key.
  • Page 9: Selecting Working Mode

    8.5. Selecting working mode Using key enter working modes menu. Using key select working mode and press The menu features the following working modes: Detailed overview of the settings of • • Weighing Percent Weighing the working modes is to be found in •...
  • Page 10 9. PERIPHERAL DEVICES CONNECTORS...
  • Page 11: Device Cleaning

    10. DEVICE CLEANING 10.1. General Recommendations Prior to cleaning, it is necessary to Use soft cloths made of microfi ber, Apply the cleanser onto the cloth fi rst. disconnect the balance from the natural fi ber or man-made fi ber. Avoid Avoid applying the cleanser directly mains.