Disassembly
1. Relieve Pressure (see cover) and unplug sprayer
from outlet.
2. Remove shroud and compressor:
a. Loosen IEC cord clamp screw and remove IEC
plug from compressor.
b. Remove air hose from compressor and remove
outlet fitting from compressor.
c. Remove four screws. Tip compressor assembly
down and forward to remove from sprayer.
Place compressor on workbench.
d. Remove two screws and IEC cord clamp.
Remove two screws and compressor shroud.
ti13414a
2
ti13409a
ti13411a
ti13416a
ti13664a
3. Loosen cooling tube nuts (70) and remove cooling
tube (71).
4. Use 1/2 in. socket to loosen and remove three bolts
(100) from head (74).
5. Use flat-blade screwdriver to pry head (74) from top
of valve plate (75) and cylinder (76) from bottom of
valve plate.
100
74
70
75
71
70
ti13937a