SETUP AND OPERATION

1) Unpack can opener and check for any loose screws or any damage.
2) Place can under the guard ring and against the locator. The can should be centered 3/16" under the ring.
3) Connect the airline. Air should be clean and dry (a 5 micron filter and coalescing filter are recommended).
Air requirement is 1-2 CFM at about 85 PSI. The valves and cylinders are pre lubricated, so no lubrication
is required.
4) Depress both palm buttons at the same time and hold until the lid is removed.
5) Remove can with both hands and remove the lid. Then the product can be dumped. Avoid sharp lid
edges.
Replace opened can with another unopened can and start again.
6)
The Model 625 opener is factory adjusted to open a standard #10 can or the particular size can
ordered. The crown punch should penetrate the can just far enough to cut off the cover but not so
far as to cause excessive splashing of liquid in can. If an adjustment is required to improve
operation of the opener, the following procedure will be used:
CAUTION: To avoid personal injury, disconnect air line before making any adjustment.
1. Disconnect airline to unit.
2. Place can to be opened under can guard.
3. Loosen the four nuts or bolts at the rear of the vertical (see drawing) and raise or lower the
head as desired, keeping the can and can guard aligned and level.
4. Tighten fasteners and close interlock door. Operate according to operating instructions.
If a new size can is required to be opened, the following procedure will be used:
1. Disconnect airline to unit.
2. Hold up the knife guard ring with one hand and with the other hand unscrew the two thumb
screws. (A flathead screwdriver may be needed to start the screws.) Let the guard ring
down and place to the side. Now hold up on the knife with one hand (being careful of any
sharp parts of the knife), and with the other hand, pull the blade clip straight out. (You may
have to wiggle the knife to loosen the blade clip.) Let the knife down. Place knife and clip
with guard ring. Do not let knife fall in the deck.
3. Install desired crown punch and can guard onto opener.
4. If can knockout pin does not align with holes in crown punch loosen screws holding them and
rotate the pins until they line up with the holes in the knife. Tighten screws and mount the
knife, clip and guard ring. If lid remains in knife, make sure knockout pins (P016) are in place and
that knife is retracting all the way.
5. Place can to be opened under can guard. If new can is taller than former size can, loosen
the four nuts or bolts at rear of vertical (see drawing) and raise head.
6. Place 1/8 –3/16 inch thick shim between can and can guard.
7. Level and align head and tighten fasteners at rear of vertical.
8. Operate according to preceding instructions.