WARNING!
1) Do not allow any person near knife or lid remover while machine is being operated. The fast, high
forces of air cylinders that operate the blade and lid remover can cause serious injuries. The two hand
controls and guards keep the operator away from these sharp, moving parts. Wear hand protection
when handling knives, open cans and lids.
2) Always disconnect air while cleaning, repairing or adjusting.
3) Check knife for wear, cracks, dents or bent teeth that could cause metal slivers or food trap areas that
are difficult to sanitize and could lead to sickness or internal injuries if can contents become
contaminated. Replace or return to the factory for repair if damaged.
4) Inspect the machine before and after operating each day or shift and after any change or adjustment
for:
1) Loose screws,
2) That the knock-out pins are straight and line up with holes in the blade backing plate and that the
mounting screws are tight,
3) That all covers and guards are in place,
4) That there isn't any broken welds and,
5) That the machine has been cleaned thoroughly.
8/4/2010