SAFETY & OPERATING INSTRUCTIONS
610
610M
CROWN PUNCH CAN OPENER, Models 610 & 610M
READ AND UNDERSTAND THIS MANUAL AND ALL INSTRUCTIONS
BEFORE OPERATING THIS OPENER.

Advertisement

Table of Contents
loading

Summary of Contents for EDLUND 610

  • Page 1 SAFETY & OPERATING INSTRUCTIONS 610M CROWN PUNCH CAN OPENER, Models 610 & 610M READ AND UNDERSTAND THIS MANUAL AND ALL INSTRUCTIONS BEFORE OPERATING THIS OPENER.
  • Page 2: Table Of Contents

    CHAPTER 1 - INTRODUCING THE EDLUND CROWN PUNCH CAN OPENER .... 1 Conventions used in this manual ........................ 1 Specifications for the Edlund CROWN PUNCH CAN OPENER, Models 610 & 610M ........ 2 CHAPTER 2 - GENERAL SAFETY RULES ..................3 Labels................................
  • Page 3: Chapter 1 - Introducing The Edlund Crown Punch Can Opener

    CHAPTER 1 - INTRODUCING THE EDLUND CROWN PUNCH CAN OPENER This manual will help you set up and safely operate your new Edlund CROWN PUNCH CAN OPENER. Careful adherence to the safety and operating instructions in this manual will ensure many years of productive use.
  • Page 4: Specifications For The Edlund Crown Punch Can Opener, Models 610 & 610M

    Specifications for the Edlund CROWN PUNCH CAN OPENER, Models 610 & 610M AIR LINE REQUIRED 85 P.S.I. at 2 C.F.M. See Figure 1 MACHINE DIMENSIONS AIR CONNECTION ¼ NPT or Quick Disconnect Edlund Company CROWN PUNCH CAN OPENER, Models 610 and 610M...
  • Page 5: Chapter 2 - General Safety Rules

    Labels Your Edlund CROWN PUNCH CAN OPENER carries prominent labels as reminders for its proper and safe use. Shown below are copies of all the labels that appear on the equipment. Take a moment to study them and make a note of their location on your Edlund CROWN PUNCH CAN OPENER before you operate the Opener.
  • Page 6: Operating The Opener Safely

    5) INSURE THE CROWN PUNCH MACHINE IS SANITIZED BEFORE OPERATION. DO NOT, UNDER ANY CONDITIONS, REMOVE, BEND, CUT, FIT, WELD, OR OTHERWISE ALTER STANDARD PARTS ON THE EDLUND CROWN PUNCH CAN OPENER. MODIFICATIONS TO YOUR MACHINE COULD CAUSE PERSONAL INJURIES AND WILL VOID YOUR WARRANTY.
  • Page 7: Additional Information And Potential Changes

    Additional Information and Potential Changes The Edlund Company, Inc. reserves the right to discontinue, change, and improve its products at any time without notice or obligation to the purchaser. The descriptions and specifications contained in this manual were in effect at printing.
  • Page 8: Chapter 3 - Setting Up Your Edlund Crown Punch Can Opener

    CHAPTER 3 - SETTING UP YOUR EDLUND CROWN PUNCH CAN OPENER This chapter covers the procedures for setting up your new EDLUND CROWN PUNCH CAN OPENER . You may find it helpful to review the Controls and Features in (Figure 2 on page 7).
  • Page 9: Edlund Crown Punch Can Opener Controls And Features

    EDLUND CROWN PUNCH CAN OPENER Controls and Features NOTE: The model shown in Figure 2 may look slightly different from your machine. Left Actuator Button Left Actuator Button Air In Quick Disconnect Air In Right Actuator (not shown) (not shown)
  • Page 10: Chapter 4 - Maintaining The Edlund Crown Punch Can Opener

    3. Tighten the four (4) "T" bolts. Ratchet Wrench not shown Tee Bolts Punch Head (Head must be level for proper operation) 1/8" (3,2 mm) 3/16" (4,8m) Thumb Screw Guard Ring Figure 3 Edlund Company CROWN PUNCH CAN OPENER, Models 610M and 610...
  • Page 11: Changing Tooling

    6. Place the can that you are opening under the guard ring against the tab and adjust the head height described in “adjusting the head” on page 8. 7. Re-connect the air supply. 8. Operate according to “Using and operation of the EDLUND CROWN PUNCH CAN OPENER" on page 6. CALL TOLL FREE 1-800-772-2126...
  • Page 12: Crown Punch Cleaning

    3. Reassemble the crown punch, guard ring, retainer clip, and the splash guard. 4. Be sure all screws are tight. 5. Reconnect the air supply. TIP: Cover the air inlet to insure water does not enter the crown punch machine when sanitizing. Edlund Company CROWN PUNCH CAN OPENER, Models 610M and 610...
  • Page 13: Chapter 5 - Troubleshooting

    If you should find a slight defect in many cases a light filing can be done, keeping a dull edge. If damage is extensive replace tooling or return it to the Edlund for re-furbishing.
  • Page 14 Air is leaking or SERVICE SHOULD ONLY BE PERFORMED BY A QUALIFIED SERVICE the crown punch TECHNICIAN. Call our Technical Support Representatives at 1-800-772-2126. does not move up or down properly. Edlund Company CROWN PUNCH CAN OPENER, Models 610M and 610...
  • Page 15 THIS PAGE INTENTIONALLY LEFT BLANK CALL TOLL FREE 1-800-722-2126...
  • Page 16: Chapter 6 - Parts Lists, Diagrams, And Warranty

    CHAPTER 6 - PARTS LISTS, DIAGRAMS, AND WARRANTY Parts List - CROWN PUNCH CAN OPENER, Models 610M & 610 NOTE: Part numbers listed are available through your authorized parts supplier. PART # DESCRIPTION A019C ADAPTER, RAM, CLIP FOR ALLEN AIR CYL...
  • Page 17 VALVE, SMC 5-WAY DBL. AIR PILOT V025 VALVE, PV-1P PULSE W010 WASHER, #10 S/S FLAT W013 WASHER, 1/2 S/S FLAT W020 WASHER, ¼" S/S LOCK W021 WASHER, #10 S/S LOCK W024 WASHER, ½" S/S LOCK W029 WASHER, #610/700 12 GA MOUNTING CALL TOLL FREE 1-800-722-2126...
  • Page 18: Head Adjustment System - Crown Punch Can Opener, Models 610M & 610

    Head Adjustment System - CROWN PUNCH CAN OPENER, Models 610M & 610 Edlund Company, LLC. CROWN PUNCH CAN OPENER, Model 610M and 610...
  • Page 19 Internal Fittings / Tooling - CROWN PUNCH CAN OPENER, Models 610M & 610 CALL TOLL FREE 1-800-722-2126...
  • Page 20 Internal Fittings - CROWN PUNCH CAN OPENER, Models 610M & 610 Edlund Company, LLC. CROWN PUNCH CAN OPENER, Model 610M and 610...
  • Page 21 CALL TOLL FREE 1-800-722-2126...
  • Page 22 Edlund Company, LLC. CROWN PUNCH CAN OPENER, Model 610M and 610...
  • Page 23 Magnet Assembly - CROWN PUNCH CAN OPENER, Model 610M Parts List PART # DESCRIPTION A008 ACTUATOR, MIN. PILOT MPA-3P A6331M ASSEMBLY, MAGNET AND BRACKET C128D CYLINDER, 1 X 1, MAGNET F036 FITTING, 1/4 OD TO 1/8 NPT F037 FITTING, 90 ELBOW, 1/4 HOSE TO 1/8 UNI F082 FITTING, 1/4 NPT TO 10-32 M003...
  • Page 24 Pneumatic Schematic - CROWN PUNCH CAN OPENER, Models 610M & 610 Edlund Company, LLC. CROWN PUNCH CAN OPENER, Model 610M and 610...